A gas-liquid chromatographic procedure employing an alkali flame ionization detector (GLC-AFID) for the quantitation of imipramine and its major active metabolite, desipramine, in plasma was developed. This method validated a previously reported radioimmunoassay for imipramine and desipramine. The GLC-AFID method was also compared with a GLC-mass spectrometric procedure which employed selected ion monitoring (GLC/MS-SIM) in which specific ions for imipramine and desipramine were monitored. The two methods using gas chromatographic separation were shown to be suitable for therapeutic monitoring of these drugs in patients. The direct immunoassay, which measures the total imipramine plus desipramine, is very useful when large numbers of samples are to be analysed rapidly and it compares favorably with the other two analytical procedures.

摘要

开发了一种采用碱火焰离子化检测器的气-液色谱法(GLC-AFID),用于定量测定血浆中的丙咪嗪及其主要活性代谢物地昔帕明。该方法验证了先前报道的丙咪嗪和地昔帕明放射免疫分析法。GLC-AFID法还与采用选择离子监测的气-质联用方法(GLC/MS-SIM)进行了比较,其中监测了丙咪嗪和地昔帕明的特定离子。这两种采用气相色谱分离的方法被证明适用于对患者体内这些药物进行治疗监测。直接免疫分析法可测定丙咪嗪和地昔帕明的总量,在需要快速分析大量样品时非常有用,且与其他两种分析方法相比具有优势。