Linscheid D, Braszczyńska Z, Osińska R
Med Pr. 1980;31(4):297-304.
Concentrations of cadmium at 9 selected workplaces were measured for 3 years. Cadmium was determined by squarewave polarography. Results ranged between 0.024 mg/m3--0.737 mg/m3 (mean concentrations). The highest concentrations occurred at cadmium electrodes production for strip plate batteries. The study of cadmium concentration along with medical examinations allowed to specify how far Vitamin C administration might affect the health status of cadmium--exposed workers.