肝脏成像:锝-99m-硫胶体与吡哌酸二乙三胺五乙酸在检测缺损中的比较。

Hepatic imaging: a comparison of Tc-99m-sulfur colloid and PIPIDA in the detection of defects.

作者信息

Floyd J L, Weiland F L, Hale A S, Nusynowitz M L

出版信息

Clin Nucl Med. 1981 Feb;6(2):53-6. doi: 10.1097/00003072-198102000-00001.

Abstract

A prospective investigation comparing Tc-99m-PIPIDA with Tc-99m-sulfur colloid in the detection of defects of the liver was carried out in 30 volunteers. By acquiring images of 1 million counts from 5-10 minutes postinjection, high quality hepatic images could be obtained with PIPIDA. Separate interpretations by three nuclear physicians yielded similar results between paired PIPIDA and sulfur colloid studies (KAV = 0.95 +/- .09, P less than 0.001). Early multiview imaging of the liver in the course of hepatobiliary evaluation with PIPIDA may yield valuable information relative to the presence of lesions.

摘要

在30名志愿者中进行了一项前瞻性研究,比较了锝-99m-吡哆醛异烟酰腙(Tc-99m-PIPIDA)与锝-99m-硫胶体在检测肝脏缺损方面的效果。通过在注射后5至10分钟采集100万计数的图像,使用PIPIDA可获得高质量的肝脏图像。三位核医学医师的独立解读显示,配对的PIPIDA和硫胶体研究结果相似(卡方值 = 0.95 ± 0.09,P < 0.001)。在使用PIPIDA进行肝胆评估过程中对肝脏进行早期多视角成像,可能会提供有关病变存在的有价值信息。