Nissanov J, Tuman R W, Gruver L M, Fortunato J M
Imaging and Computer Vision Center, Drexel University, Philadelphia, Pennsylvania, USA.
Lab Invest. 1995 Nov;73(5):734-9.
Pharmacologic control of angiogenesis is a promising new approach to the treatment of a variety of pathologic conditions including cancer. The recently developed in vitro rat aortic ring model provides a simple, reproducible assay for discovering angiogenic agonists and antagonists. However, quantification of results in this assay is time consuming, tedious, and subjective, because it involves visual inspection of images and manually counting the newly formed microvessels extending from the cultured aortic ring. This report describes an automated image analysis-based procedure for quantification of this assay that overcomes these difficulties.
The designed image processing algorithm segments the vessels from gray scale images. A high-pass filter is used, and the results are separated into nonvascular and vessel compartments based on object size and shape. Quantification relies on identification of vessels intersecting a closed transect set a fixed distance from the aortic ring. The number and the total area of these vessels are determined. The entire operation has been automated and packaged in an application called Vessels.
The correlation between computer-determined vessel area/vessel number and visual microvessel count is high (r2 = 0.91 and r2 = 0.86, respectively).
Vessels offers high-speed, fully automatic batch processing including production of a hard copy for documentation. The application runs on the Apple family of computers. On a Quadra 800, the application can process approximately 30 images/hour, which is approximately 2.5 times faster than manual quantification of this assay.
血管生成的药物控制是治疗包括癌症在内的多种病理状况的一种有前景的新方法。最近开发的体外大鼠主动脉环模型为发现血管生成激动剂和拮抗剂提供了一种简单、可重复的检测方法。然而,该检测方法的结果量化既耗时、繁琐又主观,因为它涉及对图像的目视检查以及手动计数从培养的主动脉环延伸出的新形成的微血管。本报告描述了一种基于自动图像分析的该检测方法量化程序,该程序克服了这些困难。
所设计的图像处理算法从灰度图像中分割出血管。使用高通滤波器,并根据物体大小和形状将结果分为非血管部分和血管部分。量化依赖于识别与距主动脉环固定距离处设置的封闭横断面相交的血管。确定这些血管的数量和总面积。整个操作已自动化并打包在一个名为“Vessels”的应用程序中。
计算机确定的血管面积/血管数量与目视微血管计数之间的相关性很高(分别为r2 = 0.91和r2 = 0.86)。
“Vessels”提供高速、全自动批量处理,包括生成用于记录的硬拷贝。该应用程序在苹果系列计算机上运行。在一台Quadra 800计算机上,该应用程序每小时可处理约30张图像,这比该检测方法的手动量化速度快约2.5倍。