Sjödén G O, Lundberg A, Blomgren G A
Department of Orthopedics, Karolinska Institute, Huddinge University Hospital, Sweden.
Acta Orthop Scand. 1995 Oct;66(5):391-4. doi: 10.3109/17453679508995570.
We performed total elbow replacement, using the Souter-Strathclyde prosthesis in 19 elbows of 18 patients with rheumatoid arthritis and followed the patients for 5 (1-11) years. Pain relief was achieved initially in all patients. The average range of flexion-extension was increased by 12 degrees and pronation-supination by 40 degrees. There were no infections. 1 patient sustained an intraoperative fracture of the medial epicondyle, 3 patients developed neuropathies and 1 patient had an immediate postoperative dislocation of the joint. At follow-up, 6 prostheses had radiographic loosening, with sagittal titling and migration of 4 humeral components. 2 patients had clinical symptoms of loosening.