Laser profiling: a technique for the study of prosthetic heart valve leaflet motion.

作者信息

Fenner J W, Mackay T G, Martin W, Wheatley D J

机构信息

Department of Cardiac Surgery, Royal Infirmary, Glasgow.

出版信息

Physiol Meas. 1995 Aug;16(3):181-93. doi: 10.1088/0967-3334/16/3/005.

DOI:10.1088/0967-3334/16/3/005
PMID:7488978
Abstract

A detailed understanding of the stresses and strains developed in functioning flexible-leaflet valves is necessary if a durable, non-thrombogenic heart valve replacement is to be realized. A new experimental tool, laser profiling, is presented for the study of flexible-leaflet heart valve dynamics. Profiles of moving leaflet surfaces are obtained by projecting parallel sheets of laser light onto valve leaflets as the valves open and close in a mock circulatory loop. Two versions of laser profiling have been developed. In two-dimensional mode multiple profiles are generated on a fixed plane in space but at discrete intervals in time, whereas in three-dimensional mode multiple profiles are generated across the leaflet surface at (effectively) a single instant in time. Highlighted leaflet profiles are captured by camera and transferred to an image processing system for analysis. A simple algorithm permits digitized profiles to be reconstructed within a computer-aided design software package, providing detailed visualization and quantification of valve motion. Extensive validation studies have been performed using the Medtronic-Hall mechanical prosthetic heart valve. Laser profiling enables computer reconstruction of the rigid occluder to an accuracy of +/- 200 microns from a 0.7 ms exposure taken during the period at which the occluder moves with greatest velocity. The technique has been applied to investigate the leaflet dynamics of a bovine pericardial heart valve prosthesis.

摘要

相似文献

1
Laser profiling: a technique for the study of prosthetic heart valve leaflet motion.
Physiol Meas. 1995 Aug;16(3):181-93. doi: 10.1088/0967-3334/16/3/005.
2
Dynamic in vitro quantification of bioprosthetic heart valve leaflet motion using structured light projection.
Ann Biomed Eng. 2001 Nov;29(11):963-73. doi: 10.1114/1.1415523.
3
Measurement and reconstruction of the leaflet geometry for a pericardial artificial heart valve.心包人工心脏瓣膜小叶几何形状的测量与重建。
Med Eng Phys. 2005 Mar;27(2):175-80. doi: 10.1016/j.medengphy.2004.09.017.
4
Bioprosthetic heart valve leaflet motion monitored by dual camera stereo photogrammetry.
J Biomech. 2000 Feb;33(2):199-207. doi: 10.1016/s0021-9290(99)00165-7.
5
Asynchronous closure and leaflet impact velocity of bileaflet mechanical heart valves.双叶机械心脏瓣膜的异步关闭和瓣叶撞击速度
J Heart Valve Dis. 1995 Jul;4 Suppl 1:S38-49.
6
Bioprosthetic heart valve leaflet deformation monitored by double-pulse stereo photogrammetry.通过双脉冲立体摄影测量法监测生物人工心脏瓣膜小叶变形
Ann Biomed Eng. 2002 Jan;30(1):11-8. doi: 10.1114/1.1432690.
7
Two-dimensional fluid-structure interaction simulation of bileaflet mechanical heart valve flow dynamics.双叶机械心脏瓣膜流动动力学的二维流固耦合模拟
J Heart Valve Dis. 2003 Nov;12(6):772-80.
8
Leaflet geometry extraction and parametric representation of a pericardial artificial heart valve.心包人工心脏瓣膜的瓣叶几何形状提取及参数化表示
Proc Inst Mech Eng H. 2005;219(2):143-52. doi: 10.1243/095441105X9183.
9
Laser profiling of bovine pericardial heart valves.牛心包心脏瓣膜的激光轮廓分析
Int J Artif Organs. 1997 Aug;20(8):436-9.
10
Laser assessment of leaflet closing motion in prosthetic heart valves.人工心脏瓣膜小叶关闭运动的激光评估
J Biomed Eng. 1990 Nov;12(6):477-81. doi: 10.1016/0141-5425(90)90057-t.