Ehrlich R M, Alter G
Department of Surgery, University of California, Los Angeles Center for the Health Sciences, USA.
J Urol. 1996 Jan;155(1):131-4.
Via a 2-stage procedure, 10 patients with failed hypospadias repairs were treated by a varied combination of split-thickness mesh graft urethroplasty and tunica vaginalis flap.
A bed for the mesh graft in 3 patients was provided by a tunica vaginalis flap. Tunica vaginalis flaps were also used as an intermediate layer during stage 2 of the repair.
No strictures or fistulas occurred in 8 patients. Two patients await stage 2 repair after successful stage 1 placement of the mesh graft.
The combination of split-thickness mesh graft urethroplasty and a tunica vaginalis flap appears to achieve success in the difficult patient with complex hypospadias subsequent to multiple failed repairs.