• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Atrial pacing leads: the clinical contribution of steroid elution.

作者信息

Mond H G, Hua W, Wang C C

机构信息

Department of Cardiology, Royal Melbourne Hospital, Australia.

出版信息

Pacing Clin Electrophysiol. 1995 Sep;18(9 Pt 1):1601-8. doi: 10.1111/j.1540-8159.1995.tb06981.x.

DOI:10.1111/j.1540-8159.1995.tb06981.x
PMID:7491303
Abstract

Although the original atrial pacing leads were passive fixation and J shaped for right atrial appendage placement, the subsequent development of the active fixation screw-in lead found favor because of a perceived low incidence of lead dislodgment and a wider selection of atrial pacing sites. A bipolar atrial lead study was undertaken to compare the long-term atrial implant data in 215 patients. Study leads comprised one passive fixation, steroid-eluting lead (Medtronic CapSure SP, 119 patients) and three nonsteroid-eluting leads; two active fixation (Medtronic BISPING model 4058, 30 patients; and Telectronics ACCUFIX model 330-801, 44 patients) and one passive fixation (Telectronics ENCOR model 330-854, 22 patients). Bipolar atrial voltage stimulation thresholds and electrograms were measured using the Telectronics META DDDR immediately postimplantation, and at 1-, 3-, 6-, 12-, and 18-month follow-up. There were 135 males and the mean age 68 years. The incidence of lead dislodgment was 4% for active fixation and 2% for passive fixation. All nonsteroid leads showed a typical rise in stimulation threshold with the highest being the ACCUFIX followed by the BISPING and ENCOR. The steroid-eluting CapSure SP, however, demonstrated a flat response with 98% of leads at 18 months having a value < or = 1.3 volts allowing voltage programming to 2.5 volts (2:1 safety ratio). Telemeted electrograms showed no differences for all leads at all visits. For low voltage atrial pacing with a low incidence of dislodgment and satisfactory atrial sensing, the steroid-eluting passive fixation lead is superior to all nonsteroid-eluting leads.

摘要

相似文献

1
Atrial pacing leads: the clinical contribution of steroid elution.
Pacing Clin Electrophysiol. 1995 Sep;18(9 Pt 1):1601-8. doi: 10.1111/j.1540-8159.1995.tb06981.x.
2
Chronic steroid-eluting lead performance: a comparison of atrial and ventricular pacing.慢性类固醇洗脱导线性能:心房起搏与心室起搏的比较
Pacing Clin Electrophysiol. 1997 Jan;20(1 Pt 1):17-24. doi: 10.1111/j.1540-8159.1997.tb04807.x.
3
[Modification of the detection and stimulation behavior of active and passive fixed bipolar pacemaker electrodes by depot dexamethasone].
Z Kardiol. 1997 Jul;86(7):530-7. doi: 10.1007/s003920050090.
4
High impedance low energy pacing leads: long-term results with a very small surface area steroid-eluting lead compared to three conventional electrodes.
Pacing Clin Electrophysiol. 1999 Feb;22(2):326-34. doi: 10.1111/j.1540-8159.1999.tb00446.x.
5
A 12-year experience of bipolar steroid-eluting epicardial pacing leads in children.儿童双极类固醇洗脱心外膜起搏导线的12年经验
Ann Thorac Surg. 2008 May;85(5):1704-11. doi: 10.1016/j.athoracsur.2008.02.016.
6
Long-term superiority of steroid elution in atrial active fixation platinum leads.心房主动固定铂电极导线中类固醇洗脱的长期优势
Pacing Clin Electrophysiol. 2000 Jun;23(6):1003-9. doi: 10.1111/j.1540-8159.2000.tb00888.x.
7
Steroid eluting high impedance pacing leads decrease short and long-term current drain: results from a multicenter clinical trial. CapSure Z investigators.类固醇洗脱高阻抗起搏导线可降低短期和长期电流消耗:一项多中心临床试验的结果。CapSure Z研究人员。
Pacing Clin Electrophysiol. 1999 Jan;22(1 Pt 1):39-48. doi: 10.1111/j.1540-8159.1999.tb00298.x.
8
Active fixation atrial leads: randomized comparison of two lead designs.主动固定心房电极:两种电极设计的随机对照比较
Pacing Clin Electrophysiol. 1989 Aug;12(8):1355-61. doi: 10.1111/j.1540-8159.1989.tb05049.x.
9
Atrial pacing leads following open heart surgery: active or passive fixation?心脏直视手术后的心房起搏导线:主动固定还是被动固定?
Pacing Clin Electrophysiol. 1997 Oct;20(10 Pt 1):2429-33. doi: 10.1111/j.1540-8159.1997.tb06082.x.
10
Active-fixation, steroid-eluting ventricular leads: the medium-term results in children.主动固定、类固醇洗脱心室电极:儿童的中期结果。
Anadolu Kardiyol Derg. 2005 Dec;5(4):278-82.