Suppr超能文献

自动化DNA测序的准确性:测序结果的多实验室比较

Accuracy of automated DNA sequencing: a multi-laboratory comparison of sequencing results.

作者信息

Naeve C W, Buck G A, Niece R L, Pon R T, Robertson M, Smith A J

机构信息

St. Jude Children's Research Hospital, Memphis, TN, USA.

出版信息

Biotechniques. 1995 Sep;19(3):448-53.

PMID:7495559
Abstract

A double-stranded (ds)DNA template of "unknown" sequence was distributed to approximately 80 core DNA sequencing laboratories by the Association of Biomolecular Resource Facilities (ABRF) for automated DNA sequence analysis. Forty-four different facilities responded with 83 usable sequence submissions. These sequences were grouped by both sequencing protocol (dye-primer or dye-terminator) and whether manually edited or not. The sequences were aligned with the known sequence, and the number of correct base calls, insertions, deletions, no-calls and miscalls were determined for each group. The dye-primer sequencing protocol provided the longest and most accurate sequence. The edited dye-primer data were > 95% accurate out to 400-450 bp, while the edited dye-terminator data could call only 300-350 bases at this accuracy. However, 75% of the laboratories in this sampling preferred the dye-terminator protocol, presumably because of its versatility and convenience. Laboratories that manually edited the automatically called data were able to obtain an additional 100 bases of good sequence when the dye-primer protocol was used. Surprisingly though, editing of dye-terminator results did not increase the amount of good sequence, although the dye-terminator protocol had a superior base-calling ability within the first 100 bases of called sequence.

摘要

生物分子资源设施协会(ABRF)将一个序列“未知”的双链(ds)DNA模板分发给了约80个核心DNA测序实验室,用于自动化DNA序列分析。44个不同的实验室提交了83份可用的序列。这些序列根据测序方案(染料引物或染料终止剂)以及是否经过人工编辑进行了分组。将这些序列与已知序列进行比对,并确定每组的正确碱基识别数、插入数、缺失数、无识别数和错误识别数。染料引物测序方案提供了最长且最准确的序列。经过编辑的染料引物数据在400 - 450 bp范围内的准确率超过95%,而经过编辑的染料终止剂数据在这种准确率下只能识别300 - 350个碱基。然而,在这个样本中,75%的实验室更喜欢染料终止剂方案,大概是因为它的通用性和便利性。当使用染料引物方案时,对自动识别的数据进行人工编辑的实验室能够额外获得100个碱基的良好序列。不过,令人惊讶的是,尽管染料终止剂方案在识别序列的前100个碱基内具有更好的碱基识别能力,但对染料终止剂结果的编辑并没有增加良好序列的数量。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验