Cascade P N, Wajszczuk W J, Kerin N Z, Mantel J, Rubenfire M
Cathet Cardiovasc Diagn. 1978;4(4):391-8. doi: 10.1002/ccd.1810040406.
A study of single-plane right anterior oblique left ventricular angiography was undertaken to determine the importance of obtaining correct positioning of a magnification grid and to develop a simple but accurate technique to minimize magnification errors. Theoretical and experimental volume determinations demonstrated 3% to 28% volume errors for grid placement errors ranging from 1 centimeter to 5 centimeters. An experiment was designed whereby cross table lateral radiographs of the chest were taken during contrast injections of the left ventricle. The relative position of the left ventricular center was found at a point 66% of the distance from the anterior to the posterior margin of the heart. Finding this point on noncontrast lateral films of the chest for positioning of a square centimeter grid should yield a more accurate determination of the magnification factor than other current emperic methods.
进行了一项关于单平面右前斜位左心室血管造影的研究,以确定获得放大格栅正确定位的重要性,并开发一种简单而准确的技术,以尽量减少放大误差。理论和实验体积测定表明,对于1厘米至5厘米的格栅放置误差,体积误差为3%至28%。设计了一项实验,在左心室造影剂注射期间拍摄胸部的交叉台面侧位X线片。发现左心室中心的相对位置在心脏前缘至后缘距离的66%处。在胸部的非造影侧位片上找到这一点以定位平方厘米格栅,应该比其他当前的经验方法更准确地确定放大系数。