[Influence of stress-relaxation plate on bone geometrics and mechanical property: an experimental study].

作者信息

Dai K, Dai M, Wang K

机构信息

Department of Orthopaedics, Ninth People's Hospital, Shanghai Second Medical University.

出版信息

Zhonghua Yi Xue Za Zhi. 1995 Jul;75(7):414-6, 446.

PMID:7553161
Abstract

In order to maintain the effective fixation effect of rigid bone plate in the early stage of fracture and to prevent osteoporosis induced by stress shielding effect of rigid plate in later stage of fixation, a washer made of viscoelastic material was placed between the screw and the screw hole of plate to form a stress-relaxation plate system. Both in vitro and in vivo experiments demonstrated that there was no statistical difference between the stress shielding effect of padded and unpadded plate groups. The washer showed significant deformation and damaged 8 weeks after implantation, and 10 weeks after implantation the stress shielding rate of the padded plate group was significantly lower than that of the unpadded group (P < 0.05). As a consequence, the degree of osteoporosis of the tibia in the padded group was significantly milder than the unpadded group, and 20 weeks after implantation, the diameter of the tibia medullary cavity of the padded group was significantly smaller than that of the unpadded group. The thickness of cortical bone and the bending strength of the tibia of padded group were significantly larger than those of the unpadded group (P < 0.05-0.01). These results showed that the stress-relaxation plate system can effectively maintain the stability of fracture fixation at the similar level of rigid plate during the early stage of fracture and can gradually lower down the stress shielding rate so as to prevent severe osteoporosis and reduction of bone mechanical property in the later stage of fixation.

摘要

相似文献

1
[Influence of stress-relaxation plate on bone geometrics and mechanical property: an experimental study].
Zhonghua Yi Xue Za Zhi. 1995 Jul;75(7):414-6, 446.
2
[An experimental study of the effects of stress-relaxation plate on bone remodeling].应力松弛接骨板对骨重塑影响的实验研究
Zhonghua Wai Ke Za Zhi. 1995 Nov;33(11):698-700.
3
Stress-relaxation plates and the remodeling of callus and cortex under the plate in rabbits.应力松弛接骨板与兔接骨板下骨痂及皮质骨的重塑
Chin Med J (Engl). 2000 Sep;113(9):805-9.
4
[Stress shielding and fracture healing].
Zhonghua Yi Xue Za Zhi. 1994 Aug;74(8):483-5, 519.
5
[Biomechanic study on length of plate in treatment of tibial shaft fracture].[钢板长度治疗胫骨干骨折的生物力学研究]
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2008 Nov;22(11):1323-6.
6
[Biomechanical studies of the role of the interfragmentary traction screw in plate osteosynthesis exemplified by a short oblique tibial shaft fracture].
Aktuelle Traumatol. 1986 Apr;16(2):60-6.
7
Biomechanical and histological evaluation of the application of biodegradable poly-L-lactic cushion to the plate internal fixation for bone fracture healing.可生物降解聚-L-乳酸垫片在骨折愈合钢板内固定中的应用的生物力学与组织学评估
Clin Biomech (Bristol). 2008;23 Suppl 1:S7-S16. doi: 10.1016/j.clinbiomech.2008.01.005. Epub 2008 Mar 4.
8
[Effect of fixative duration on recovery of local osteoporosis induced by rigid plate].[固定时间对刚性接骨板所致局部骨质疏松恢复的影响]
Zhonghua Wai Ke Za Zhi. 1991 Nov;29(11):698-700, 719.
9
Cortical bone perfusion in plated fractured sheep tibiae.钢板固定的绵羊胫骨骨折处的皮质骨灌注情况
J Orthop Res. 1995 Sep;13(5):715-24. doi: 10.1002/jor.1100130511.
10
Reduction of stress shielding beneath a bone plate by use of a polymeric underplate. An experimental study in dogs.
Clin Orthop Relat Res. 1989 Sep(246):293-9.