Eventov V L, Andrianova M Iu, Maksimenko V A
Urol Nefrol (Mosk). 1995 Jul-Aug(4):25-7.
The efficacy of artificial kidney apparatuses was assessed by using 5 different methods of regenerating the dialysis solution. In the series of model experiments the authors have studied the quality of the solution purification from urea, creatinine, uric acid, nonorganic phosphorus and potassium ions. Clinical trial of the regeneration systems was performed in patients with chronic renal failure on preparation for renal transplantation. The efficacy of the regeneration systems by elimination from the blood of metabolic products was not inferior to the standard hemodialysis system working in the discharge mode. The most promising method was that of electrochemical regeneration of the dialysis solution.
通过使用5种不同的透析液再生方法评估了人工肾装置的功效。在一系列模型实验中,作者研究了从尿素、肌酐、尿酸、无机磷和钾离子中纯化溶液的质量。在准备进行肾移植的慢性肾衰竭患者中进行了再生系统的临床试验。通过从血液中清除代谢产物来评估再生系统的功效,其并不逊色于以排放模式运行的标准血液透析系统。最有前景的方法是透析液的电化学再生。