Li S J, Jin G Y, Fish B L, Moulder J E
Biophysics Research Institute, Medical College of Wisconsin, Milwaukee 53226, USA.
Radiat Res. 1995 Jul;143(1):45-53.
Hypoxic fractions were measured in multiple tumor models and compared to 31P magnetic resonance spectroscopy (MRS) parameters. Hypoxic fractions were measured by excision assays in intramuscular and subcutaneous RIF-1 tumors, large and small SCCVII tumors, and KHT tumors. The hypoxic fractions ranged from 3% (small SCCVII) to 21% (KHT). Measurements of 31P MRS parameters (indices of tumor metabolism) were made under the same conditions used in the hypoxic fraction assays. The PCR/Pi ratios in the five tumor models were strongly correlated (r2 = 0.98, tau = 1.00, P < 0.02) with their hypoxic fractions, and the NTP/Pi ratio was weakly correlated (r2 = 0.67, tau = 0.60, P < 0.17) with hypoxic fraction. Smaller values of the PCr/Pi and NTP/Pi ratios were found in the tumors with larger hypoxic fractions. These experiments indicate that 31P MRS may provide a relative measurement of hypoxic fractions across different tumor lines that can be applied non-invasively to individual tumors.
在多个肿瘤模型中测量了缺氧分数,并与磷-31磁共振波谱(MRS)参数进行比较。通过切除测定法测量了肌肉内和皮下的RIF-1肿瘤、大小不同的SCCVII肿瘤以及KHT肿瘤的缺氧分数。缺氧分数范围从3%(小SCCVII肿瘤)到21%(KHT肿瘤)。在与缺氧分数测定相同的条件下进行磷-31 MRS参数(肿瘤代谢指标)的测量。五个肿瘤模型中的磷酸肌酸/无机磷(PCR/Pi)比率与其缺氧分数高度相关(r2 = 0.98,τ = 1.00,P < 0.02),而核苷三磷酸/无机磷(NTP/Pi)比率与缺氧分数弱相关(r2 = 0.67,τ = 0.60,P < 0.17)。在缺氧分数较高的肿瘤中发现磷酸肌酸/无机磷和核苷三磷酸/无机磷比率的值较小。这些实验表明,磷-31 MRS可以提供不同肿瘤系缺氧分数的相对测量值,且可无创地应用于个体肿瘤。