Bolin A, Eliasson S
Department of Oral Radiology, School of Dentistry, Karolinska Institutet, Stockholm, Sweden.
Swed Dent J. 1995;19(1-2):65-71.
Accurate information on available bone volume is of decisive importance in dental implantology. The purpose of the present investigation was to examine the correlation between maxillary alveolar bone height measured on panoramic radiographs and on tomographic radiographs with a facio-lingual dimension of at least 5 mm. The alveolar bone height was recorded in 683 edentulous and dentate regions in 100 patients. The mean bone height (m +/- SD) in panoramic radiography for all regions was 11.90 +/- 3.60 mm and in tomography 8.20 +/- 4.33 mm. The differences in bone height recorded by the two techniques were greater in edentulous regions than in dentate regions, and the differences increased in regions where the available bone height was small. For preimplant assessment of available bone height in the maxilla, tomography is recommended for all regions intended for implants.
在牙种植学中,有关可用骨量的准确信息至关重要。本研究的目的是检验全景X线片上测量的上颌牙槽骨高度与断层X线片上测量的牙槽骨高度之间的相关性,断层X线片的颊舌径至少为5毫米。记录了100例患者683个无牙区和有牙区的牙槽骨高度。所有区域在全景X线片上的平均骨高度(m±SD)为11.90±3.60毫米,在断层X线片上为8.20±4.33毫米。两种技术记录的骨高度差异在无牙区比有牙区更大,且在可用骨高度较小的区域差异增大。对于上颌可用骨高度的种植前评估,建议对所有拟植入种植体的区域进行断层扫描。