[Machine-assisted detection of individually effective minimal CPAP pressure using the Vitalog HMS 5000 monitor].

作者信息

Juhász J, Schillen J, Urbigkeit A, Penzel T, Becker H, Peter J H

机构信息

Medizinische Poliklinik, Philipps Universität, Marburg.

出版信息

Pneumologie. 1995 Mar;49 Suppl 1:199-204.

PMID:7617615
Abstract

UNLABELLED

Continuous positive airway pressure ventilation (CPAP) has been proven to be highly effective in the elimination of sleep-related breathing disorders (SRBD) in the last couple of years. The titration of the effective airway pressure should be carried out under continuous polysomnographic supervision in the sleep laboratory. The CPAP ventilation may result in potential hazards through the positive airway pressure and each patient needs an individually adjusted pressure for therapy. In a prospective study we investigated under polysomnographic supervision the effectivity and the hazards of a machine-controlled CPAP calibration in 22 male patients (pts) (age: 53.6 +/- 8.9 years, BMI: 29.9 +/- 5.0 kg/m2) with obstructive SRBD (RDI: 50.6 +/- 1/h). Automatic CPAP-calibrations were carried out using the Vitalog HMS-5000 monitor and the Respironics BiPAP-STD ventilator. An algorithm determined the cyclical changes of the airway pressure. The following night we controlled the assessed pressure through manual adjustment during conventional polysomnography.

RESULTS

The CPAP-levels assessed through the automatic calibrations (8.36 +/- 2.36 cmH2O) showed in 19 pts a good agreement with the CPAP-levels of the control nights (8.15 +/- 2.36 cmH2O), the difference was statistically nonsignificant (p < 0.5). The CPAP-levels of the automatic titrations and the control nights agreed exactly in 12 pts (63%). 3 pts of the 22 failed the automatic CPAP-titration process because of functional or psychical reasons. 14 pts (64% of 22 pts) showed a good functional tolerance to the cyclical changes of the airway pressure. 3 pts were unable to fall asleep under the increasing airway pressure, but after falling asleep at a constant pressure of 2 or 4 cmH2O they could tolerate the automatic pressure titration. A reset of the actual pressure to the baseline was necessary in 13 pts to enable them falling asleep, in 2 pts because of increase of the airway pressure due to movement artifacts, in 2 pts because of central apneas and in one patient because of ventricular extrasystoles. 35 increases of the baseline level (48% of altogether 73 increases) occurred due to clinically irrelevant desaturations. We found a direct hazardous effect of the machine-controlled CPAP-titration (central apneas, secondary alveolar hypoventilation, ventricular extrasystole) in 7 pts with chronic obstructive pulmonary disease and/or cardiovascular disorder.

CONCLUSION

The machine-controlled CPAP-titration should be carried out only in a selected group of patients. Nevertheless, despite of the good agreement of the assessed pressure levels with the polysomnographic controls, this method seems to be not suitable for the clinical routine because of its potential hazards and contraindications in high risk patients.

摘要

相似文献

1
[Machine-assisted detection of individually effective minimal CPAP pressure using the Vitalog HMS 5000 monitor].
Pneumologie. 1995 Mar;49 Suppl 1:199-204.
2
Unattended continuous positive airway pressure titration. Clinical relevance and cardiorespiratory hazards of the method.无人值守持续气道正压通气滴定。该方法的临床相关性及心肺风险
Am J Respir Crit Care Med. 1996 Aug;154(2 Pt 1):359-65. doi: 10.1164/ajrccm.154.2.8756807.
3
Treatment of obstructive sleep apnea with a self-titrating continuous positive airway pressure (CPAP) system.使用自动调压持续气道正压通气(CPAP)系统治疗阻塞性睡眠呼吸暂停。
Sleep. 1996 Jul;19(6):497-501. doi: 10.1093/sleep/19.6.497.
4
[Effect of automatically titrated CPAP systems on sleep and respiration in sleep apnea syndrome].[自动滴定持续气道正压通气系统对睡眠呼吸暂停综合征患者睡眠及呼吸的影响]
Wien Med Wochenschr. 1996;146(13-14):385-7.
5
[Indications and application of BiPaP therapy].
Pneumologie. 1993 Mar;47 Suppl 1:184-8.
6
Sleep-related breathing disorders in acute respiratory failure assisted by non-invasive ventilatory treatment: utility of portable polysomnographic system.无创通气治疗辅助的急性呼吸衰竭中与睡眠相关的呼吸障碍:便携式多导睡眠图系统的效用
Respir Med. 2000 Feb;94(2):128-34. doi: 10.1053/rmed.1999.0682.
7
Accuracy of a novel auto-CPAP device to evaluate the residual apnea-hypopnea index in patients with obstructive sleep apnea.一种新型自动持续气道正压通气设备评估阻塞性睡眠呼吸暂停患者残余呼吸暂停低通气指数的准确性
Sleep Breath. 2015 May;19(2):569-78. doi: 10.1007/s11325-014-1048-z. Epub 2014 Aug 13.
8
Practice parameters for the use of continuous and bilevel positive airway pressure devices to treat adult patients with sleep-related breathing disorders.使用持续气道正压通气和双水平气道正压通气设备治疗成人睡眠相关呼吸障碍患者的实践参数。
Sleep. 2006 Mar;29(3):375-80. doi: 10.1093/sleep/29.3.375.
9
[Computer-assisted nCPAP settings in comparison with conventional methods].
Pneumologie. 1997 Aug;51 Suppl 3:754-7.
10
Automatic pressure titration with APAP is as effective as manual titration with CPAP in patients with obstructive sleep apnea.对于阻塞性睡眠呼吸暂停患者,使用自动调压持续气道正压通气(APAP)进行自动压力滴定与使用持续气道正压通气(CPAP)进行手动滴定一样有效。
Respiration. 2007;74(3):279-86. doi: 10.1159/000100364. Epub 2007 Feb 23.

引用本文的文献

1
Automatic nasal continuous positive airway pressure titration in the laboratory: patient outcomes.实验室自动鼻持续气道正压滴定:患者结局
Thorax. 1997 Jan;52(1):72-5. doi: 10.1136/thx.52.1.72.