I-123 iodoamphetamine lung scanning in patients with ventilation-perfusion mismatching.

作者信息

Hirose Y, Hayashida K, Ishida Y, Takamiya M, Nishimura T

机构信息

Department of Radiology, National Cardiovascular Center, Osaka, Japan.

出版信息

Clin Nucl Med. 1995 May;20(5):421-5. doi: 10.1097/00003072-199505000-00010.

Abstract

I-123 IMP is a nonparticulate agent and becomes trapped by endothelial membranes in the pulmonary capillaries. Using I-123 IMP, the authors studied six patients with ventilation-perfusion mismatch. Three of six patients had pulmonary thromboembolism, and three had pulmonary hypertension. In comparison with conventional perfusion lung scanning using Tc-99m MAA, defect sizes visualized by I-123 IMP were smaller in all patients. I-123 iodoamphetamine is a useful agent for assessing the perfusion of pulmonary arterial microvasculature which Tc-99m MAA fails to penetrate.

摘要

I-123异丁基苄胍是一种非颗粒性制剂,可被肺毛细血管的内皮膜捕获。作者使用I-123异丁基苄胍对6例通气-灌注不匹配患者进行了研究。6例患者中有3例患有肺血栓栓塞症,3例患有肺动脉高压。与使用Tc-99m MAA的传统灌注肺扫描相比,I-123异丁基苄胍显示的缺损大小在所有患者中均较小。I-123碘安非他明是一种用于评估肺动脉微血管灌注的有用制剂,而Tc-99m MAA无法穿透该微血管。