Kao J T, Tibone J E, Shaffer B
Department of Orthopedics, Kaiser Foundation Hospital, San Francisco, CA 94118, USA.
Am J Knee Surg. 1995 Spring;8(2):42-7.
This article retrospectively reviews the last 89 ACL reconstructions done over the past 24 months by the senior author and also investigates the pullout strength of a 15-mm long interference screw in cadaveric knees. Results revealed that interference screw fixation at the tibial tunnel during endoscopic ACL reconstruction should almost always be possible by ensuring a tibial tunnel with adequate length, taking additional bone on the graft from the proximal tibia, twisting the graft, and possibly using a 15-mm interference screw.
本文回顾性分析了资深作者在过去24个月内进行的89例前交叉韧带重建手术,并研究了15毫米长的挤压螺钉在尸体膝关节中的拔出强度。结果显示,在内镜下前交叉韧带重建术中,通过确保胫骨隧道有足够的长度、从胫骨近端获取额外的骨块用于移植物、扭转移植物以及可能使用15毫米的挤压螺钉,几乎总能实现胫骨隧道的挤压螺钉固定。