Suppr超能文献

使用铊-201检测未经治疗的儿童霍奇金病。

Use of Tl-201 to detect untreated pediatric Hodgkin disease.

作者信息

Fletcher B D, Kauffman W M, Kaste S C, Winer-Muram H T, Fang L, Chen G, Hudson M

机构信息

Department of Diagnostic Imaging, St Jude Children's Research Hospital, Memphis, TN 38101-0318, USA.

出版信息

Radiology. 1995 Sep;196(3):851-5. doi: 10.1148/radiology.196.3.7644655.

Abstract

PURPOSE

To evaluate the usefulness of thallium-201 scintigrams in depiction of supradiaphragmatic lymphadenopathy associated with newly diagnosed Hodgkin disease in pediatric patients.

MATERIALS AND METHODS

Thallium-201 and gallium-67 scans of the chest and neck were obtained in 33 consecutive patients. Mediastinal, cervical, supraclavicular, and axillary lymph node activity was evaluated by independent raters, and results were compared in a blinded fashion with those on chest computed tomographic (CT) scans.

RESULTS

Gallium and thallium scans demonstrated similar accuracy in depiction of CT-defined mediastinal masses. The kappa statistic indicated moderate to strong agreement with CT results. Similarly, there was no statistically significant difference between the accuracy of thallium and gallium scans in depiction of extramediastinal lymphadenopathy.

CONCLUSION

Thallium scintigraphy is effective for depiction of lymphadenopathy in pediatric patients with untreated Hodgkin disease. Serial thallium studies may provide an alternative to gallium scans in monitoring response to treatment.

摘要

目的

评估铊-201闪烁扫描在描绘小儿新诊断霍奇金病相关的膈上淋巴结病中的作用。

材料与方法

对33例连续患者进行胸部和颈部的铊-201及镓-67扫描。由独立评估者评估纵隔、颈部、锁骨上及腋窝淋巴结活性,并将结果与胸部计算机断层扫描(CT)的结果进行盲法比较。

结果

镓扫描和铊扫描在描绘CT界定的纵隔肿块方面显示出相似的准确性。kappa统计量表明与CT结果有中度到高度的一致性。同样,铊扫描和镓扫描在描绘纵隔外淋巴结病的准确性方面无统计学显著差异。

结论

铊闪烁扫描对描绘未经治疗的小儿霍奇金病患者的淋巴结病有效。连续铊扫描研究在监测治疗反应方面可能为镓扫描提供一种替代方法。