丹磺酰多胺在高效薄层色谱板上的降解

Degradation of dansyl polyamines on high-performance thin-layer chromatographic plates.

作者信息

Rustenbeck I, Löptien D, Lenzen S

机构信息

Institute of Pharmacology and Toxicology, University of Göttingen, Germany.

出版信息

J Chromatogr B Biomed Appl. 1995 May 5;667(1):185-7. doi: 10.1016/0378-4347(94)00596-w.

Abstract

Using high-performance thin-layer chromatography with in situ quantitation to measure dansylated polyamines in the range of 1-20 pmol, we found that dansylated polyamines apparently react with the silica gel of the plates. The fluorescence of the dansyl polyamines diminished with increase in the time interval between application of a sample to the plate and start of the chromatographic separation. Conversely, the fluorescence at the site of application increased with the length of the time interval, indicating the formation of polar reaction products. If this reaction is not accounted for, considerable errors in quantitation of dansyl polyamines may occur.

摘要

使用具有原位定量功能的高效薄层色谱法来测量1-20皮摩尔范围内的丹磺酰化多胺时,我们发现丹磺酰化多胺明显与板上的硅胶发生反应。从将样品点到板上至开始色谱分离的时间间隔增加时,丹磺酰化多胺的荧光会减弱。相反,点样处的荧光随时间间隔的延长而增加,这表明形成了极性反应产物。如果不考虑这种反应,可能会在丹磺酰化多胺的定量中出现相当大的误差。