Saha S, Williams P A
Department of Orthopaedic Surgery, Loma Linda University, CA 92354, USA.
J Orthop Res. 1995 Jul;13(4):524-32. doi: 10.1002/jor.1100130407.
We compared the electrical and dielectric properties of wet human cortical and cancellous bone tissue from the distal tibia. The relationships between the electrical and dielectric behavior of cortical and cancellous bone and variables of measurement such as frequency and direction (orientation) were evaluated. In general, the resistivity of human cortical bone was found to be approximately 3.1 times more than that of cancellous bone in the longitudinal direction and least 25 times more in the transverse directions. The dielectric permittivity of human cortical bone was approximately 3.9 times that of cancellous bone in the longitudinal direction, whereas in the transverse directions it was about 0.65 times greater. Measurement variables such as frequency and orientation appeared to affect cancellous and cortical bone differently. Strong correlations were found between the electrical properties in one direction and the electrical properties in the other two directions; however, these relationships differed for the samples of cortical and cancellous bone.
我们比较了来自胫骨远端的湿人类皮质骨和松质骨组织的电学和介电特性。评估了皮质骨和松质骨的电学和介电行为与诸如频率和方向(取向)等测量变量之间的关系。一般来说,发现人类皮质骨在纵向的电阻率约为松质骨的3.1倍,在横向至少为松质骨的25倍。人类皮质骨在纵向的介电常数约为松质骨的3.9倍,而在横向则约大0.65倍。频率和取向等测量变量对松质骨和皮质骨的影响似乎不同。在一个方向上的电学特性与另外两个方向上的电学特性之间发现了强相关性;然而,这些关系在皮质骨和松质骨样本中有所不同。