Absorbed energy distribution from radiofrequency electromagnetic radiation in a mammalian cell model: effect of membrane-bound water.

作者信息

Liu L M, Cleary S F

机构信息

Physiology Department, Medical College of Virginia, Virginia Commonwealth University, Richmond 23298, USA.

出版信息

Bioelectromagnetics. 1995;16(3):160-71. doi: 10.1002/bem.2250160304.

DOI:10.1002/bem.2250160304
PMID:7677792
Abstract

The spatial distributions of induced 27 or 2450 MHz radiofrequency (RF) electric fields (E-fields) and specific absorption rates (SARs) in a three-component spherical cell model (cytoplasm, membrane, extracellular space) were determined by Mie scattering theory. The results were compared to results for the same cell model but with 0.5 nm thick of bound water on the inner (cytoplasmic) and outer (extracellular) membrane surfaces (i.e., five-component cell model). The results provide insight regarding direct frequency-dependent RF radiation effects at the cellular level. Induced E-fields and SARs were calculated for two bound-water characteristic frequencies (400 or 1000 MHz) and ionic conductivities (1-1000 mS/m). In order to estimate the dependence of the results on bound water within the membrane per se, the model was revised to include bound water within the inner and outer membrane surfaces. The results were as follows: 1) on the x-axis, the y- and z-components of the induced E-field were of insignificant magnitude compared to the x-component for an incident E-field parallel to the x-axis; 2) the ratio of transmembrane E-fields induced by 2450 MHz vs. 27 MHz RF [i.e., Ex (2450 MHz)/Ex (27 MHz)] was 0.1; 3) for the three-component cell model, the corresponding SAR ratios [SAR (2450 MHz)/SAR (27MHz)] in the cytoplasm and extracellular space were 1.66 and 5.0, respectively; 4) the SAR rations [SAR (2450 MHz)/SAR (27 MHz)] for the cytoplasm and extracellular space for the five-component cell model were 1.66 and 5.0, respectively; 5) the ratio of the E-fields induced in the cytoplasmic and extracellular layers of bound water in the five-component cell model [E (2450 MHz)/ E (27Mhz)] were 0.62 and 0.63, respectively; 6) the SAR ratios [SAR (2450 MHz)/SAR (27 MHz)] for the cytoplasmic and extracellular bound-water layers were 66 and 65.3, respectively; and 7) variation of bound-water characteristic frequency, ionic conductivity, or bound-water incorporation inside the membrane surfaces, per se, did not significantly affect the E-field or SAR ratios. These results indicate that frequency-dependent nonuniformities may occur in the distribution of induced RF E-fields and SARs at the cellular level.

摘要

相似文献

1
Absorbed energy distribution from radiofrequency electromagnetic radiation in a mammalian cell model: effect of membrane-bound water.
Bioelectromagnetics. 1995;16(3):160-71. doi: 10.1002/bem.2250160304.
2
[GSM 1,800 MHz radiofrequency electromagnetic fields induced clustering of membrane surface receptors and interference by noise magnetic fields].[GSM 1800兆赫兹射频电磁场诱导膜表面受体聚集及噪声磁场的干扰]
Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi. 2006 Aug;24(8):461-4.
3
Analysis of the influence of the cell geometry, orientation and cell proximity effects on the electric field distribution from direct RF exposure.分析细胞几何形状、取向和细胞邻近效应对直接射频暴露下电场分布的影响。
Phys Med Biol. 2001 Jan;46(1):213-25. doi: 10.1088/0031-9155/46/1/315.
4
Theoretical and experimental determination of SAR patterns for spherical tissue models in a rectangular resonant cavity.
Bioelectromagnetics. 1984;5(1):89-99. doi: 10.1002/bem.2250050110.
5
Radio frequency electromagnetic exposure: tutorial review on experimental dosimetry.射频电磁辐射暴露:实验剂量学教程综述
Bioelectromagnetics. 1996;17(3):195-208. doi: 10.1002/(SICI)1521-186X(1996)17:3<195::AID-BEM5>3.0.CO;2-Z.
6
Cell physiological effects of radiofrequency electromagnetic fields.
Physiol Chem Phys. 1982;14(1):31-9.
7
The effect of frequency (64-498 MHz) on specific absorption rate adjacent to metallic orthopedic screws in MRI: A numerical simulation study.磁共振成像中邻近金属骨科螺钉的频率(64-498 MHz)对吸收率的影响:一项数值模拟研究。
Med Phys. 2024 Feb;51(2):1074-1082. doi: 10.1002/mp.16902. Epub 2023 Dec 20.
8
Near-field radiofrequency electromagnetic exposure assessment.近场射频电磁暴露评估
Electromagn Biol Med. 2015 Sep;34(3):180-2. doi: 10.3109/15368378.2015.1076444.
9
RF currents induced in an anatomically-based model of a human for plane-wave exposures (20-100 MHz).在基于人体解剖模型上针对平面波暴露(20 - 100兆赫兹)所感应出的射频电流。
Health Phys. 1989 Jul;57(1):89-98. doi: 10.1097/00004032-198907000-00011.
10
[Anthropometric differentiation of effects of radiofrequency electromagnetic fields of frequency 100 MHz on workers].[100兆赫射频电磁场对工人影响的人体测量学差异]
Med Pr. 2014;65(3):351-60.

引用本文的文献

1
The Synergy of Thermal and Non-Thermal Effects in Hyperthermic Oncology.热疗肿瘤学中热效应与非热效应的协同作用
Cancers (Basel). 2024 Nov 21;16(23):3908. doi: 10.3390/cancers16233908.
2
Heterogeneous Heat Absorption Is Complementary to Radiotherapy.非均匀热吸收与放射治疗相辅相成。
Cancers (Basel). 2022 Feb 11;14(4):901. doi: 10.3390/cancers14040901.
3
Comparison of biological effects of modulated electro-hyperthermia and conventional heat treatment in human lymphoma U937 cells.调制式电高热疗法与传统热处理对人淋巴瘤U937细胞生物学效应的比较。
Cell Death Discov. 2016 Jun 13;2:16039. doi: 10.1038/cddiscovery.2016.39. eCollection 2016.
4
Effects of a specially pulsed electric field on an animal model of wound healing.一种特殊脉冲电场对伤口愈合动物模型的影响。
Lasers Med Sci. 2009 Sep;24(5):735-40. doi: 10.1007/s10103-008-0631-6. Epub 2008 Dec 5.