Kon N D, Westaby S, Amarasena N, Pillai R, Cordell A R
Department of Cardiothoracic Surgery, Bowman Gray School of Medicine, Winston-Salem, North Carolina 27103.
Ann Thorac Surg. 1995 Apr;59(4):857-62. doi: 10.1016/0003-4975(95)00066-t.
Stentless porcine aortic valves demonstrate superior hemodynamic performance when compared with their stented counterparts. The technical considerations for implanting these valves can be demanding. The Medtronic Freestyle aortic root bioprosthesis resembles an allograft, has zero-pressure-fixed leaflets treated with an antimineralization agent, and can be implanted using a variety of techniques. In this study of that valve, total root replacement (TRR) was compared with a partial scallop aortic inclusion technique (PSI). Implications were performed in 75 patients (49 PSI and 26 TRR). There were no significant differences with respect to age, sex, or incidence of concomitant procedures. Mean aortic cross-clamp times were significantly less in the PSI group than in the TRR group (51.8 +/- 11.7 minutes versus 125.5 +/- 19.7 minutes; p = 0.0001). At discharge, mean systolic gradients seen on color-flow Doppler echocardiography were less in the TRR group than in the PSI group (6.17 +/- 3.66 versus 10.01 +/- 4.83 mm Hg; p = 0.014). Discharge echocardiography revealed trivial valve regurgitation in 8.3% of the TRR group and in 41.7% of the PSI group (p = 0.004). No patient experienced any significant valvular regurgitation on discharge echocardiography. We conclude that early experience with the Medtronic Freestyle aortic root bioprosthesis shows excellent short-term function regardless of implantation technique. Shorter cross-clamp times, comparable with those of stented valve procedures, occurred with PSI implantation. We anticipate that effects on long-term durability will be beneficial.
与带支架的猪主动脉瓣相比,无支架猪主动脉瓣展现出更优的血流动力学性能。植入这些瓣膜的技术考量可能颇具挑战性。美敦力Freestyle主动脉根部生物假体类似于同种异体移植物,其瓣叶经抗矿化剂处理后零压力固定,且可用多种技术植入。在这项针对该瓣膜的研究中,将全根部置换(TRR)与部分扇贝主动脉纳入技术(PSI)进行了比较。对75例患者(49例采用PSI,26例采用TRR)进行了分析。在年龄、性别或同期手术发生率方面无显著差异。PSI组的平均主动脉阻断时间显著短于TRR组(51.8±11.7分钟对125.5±19.7分钟;p = 0.0001)。出院时,彩色多普勒超声心动图显示TRR组的平均收缩期压差低于PSI组(6.17±3.66对10.01±4.83 mmHg;p = 0.014)。出院超声心动图显示TRR组8.3%的患者有轻微瓣膜反流,PSI组为41.7%(p = 0.004)。出院超声心动图检查未发现任何患者有明显的瓣膜反流。我们得出结论,无论采用何种植入技术,美敦力Freestyle主动脉根部生物假体的早期经验均显示出优异的短期功能。PSI植入的主动脉阻断时间较短,与带支架瓣膜手术相当。我们预计这对长期耐久性将产生有益影响。