Chorro F J, Sanchis J, López-Merino V, Burguera M, Martinez-Mas M L, Cortina J, Such L
Department of Medicine, University Clinic Hospital, Valencia, Spain.
Eur Heart J. 1994 Dec;15(12):1681-8. doi: 10.1093/oxfordjournals.eurheartj.a060452.
Subthreshold stimuli trains may inhibit the response to a subsequent suprathreshold stimulus; the inhibitory effect decreases or even disappears when the subthreshold stimuli are delivered apart from the suprathreshold stimulus. The purpose of this study is to analyse, in atrial epicardium, the influence of different electrode configurations upon the inhibitory effect of subthreshold stimuli trains delivered at a short distance from the explored zone. In 18 anaesthetized dogs, the basal atrial effective refractory period was determined using an epicardial unipolar cathodal electrode. A second determination was performed when a subthreshold stimuli train (1 ms cathodal pulses, 800 Hz, and intensity 10% less than the diastolic threshold of the train) was delivered prior to the extrastimulus through: (a) 8 electrodes equidistant (4.5 mm) from the central test electrode (Group 1, n = 5); (b) a 1 mm wide ring electrode, 2.5 mm from the central test electrode (Group 2, n = 7); and (c) a 3.5 mm wide ring electrode, 2.5 mm from the central test electrode (Group 3, n = 6). A third determination was performed in all experiments delivering both the subthreshold stimuli train and the extrastimulus through the same central test electrode. Atrial effective refractory period did not vary significantly with respect to the basal values in Group 1 (141 +/- 22 vs 142 +/- 25 ms; ns) though it increased in Group 2 (168 +/- 27 vs 142 +/- 18 ms; P < 0.01) and in Group 3 (160 +/- 20 vs 133 +/- 25 ms; P < 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)
阈下刺激串可能会抑制对随后阈上刺激的反应;当阈下刺激与阈上刺激分开施加时,抑制作用会减弱甚至消失。本研究的目的是分析在心房心外膜中,不同电极配置对在距探测区域短距离处施加的阈下刺激串的抑制作用的影响。在18只麻醉犬中,使用心外膜单极阴极电极测定基础心房有效不应期。在额外刺激之前通过以下方式施加阈下刺激串(1毫秒阴极脉冲,800赫兹,强度比刺激串的舒张阈值低10%)后进行第二次测定:(a) 8个与中央测试电极等距(4.5毫米)的电极(第1组,n = 5);(b) 一个距中央测试电极2.5毫米的1毫米宽环形电极(第2组,n = 7);以及(c) 一个距中央测试电极2.5毫米的3.5毫米宽环形电极(第3组,n = 6)。在所有实验中,通过同一个中央测试电极施加阈下刺激串和额外刺激,进行第三次测定。第1组的心房有效不应期与基础值相比无显著变化(141±22对142±25毫秒;无显著性差异),而第2组(168±27对142±18毫秒;P<0.01)和第3组(160±20对133±25毫秒;P<0.01)的心房有效不应期增加。(摘要截断于250字)