Suppr超能文献

与肌管中T型钙电流相关的钙瞬变。

Calcium transients associated with the T type calcium current in myotubes.

作者信息

García J, Beam K G

机构信息

Department of Physiology, Colorado State University, Fort Collins 80523.

出版信息

J Gen Physiol. 1994 Dec;104(6):1113-28. doi: 10.1085/jgp.104.6.1113.

Abstract

Immature skeletal muscle cells, both in vivo and in vitro, express a high density of T type calcium current and a relatively low density of the dihydropyridine receptor, the protein thought to function as the Islow calcium channel and as the voltage sensor for excitation-contraction coupling. Although the role of the voltage sensor in eliciting elevations of myoplasmic, free calcium (calcium transients) has been examined, the role of the T type current has not. In this study we examined calcium transients associated with the T type current in cultured myotubes from normal and dysgenic mice, using the whole cell configuration of the patch clamp technique in conjunction with the calcium indicator dye Fluo-3. In both normal and dysgenic myotubes, the T type current was activated by weak depolarizations and was maximal for test pulses to approximately -20 mV. In normal myotubes that displayed T type calcium current, the calcium transient followed the amplitude and the integral of the current at low membrane potentials (-40 to -20 mV) but not at high potentials, where the calcium transient is caused by SR calcium release. The amplitude of the calcium transient for a pulse to -20 mV measured at 15 ms after depolarization represented, on average, 4.26 +/- 0.68% (n = 19) of the maximum amplitude of the calcium transient elicited by strong, 15-ms test depolarizations. In dysgenic myotubes, the calcium transient followed the integral of the calcium current at all test potentials, in cells expressing only T type current as well as in cells possessing both T type current and the L type current Idys. Moreover, the calcium transient also followed the amplitude and time course of current in dysgenic myotubes expressing the cardiac, DHP-sensitive calcium channel. Thus, in those cases where the transient appears to be a consequence of calcium entry, it has the same time course as the integral of the calcium current. Inactivation of the T type calcium current with 1-s prepulses, or block of the current by the addition of amiloride (0.3-1.0 mM) caused a reduction in the calcium transient which was similar in normal and dysgenic myotubes. To allow calculation of expected changes of intracellular calcium in response to influx, myotubes were converted to a roughly spherical shape (myoballs) by adding 0.5 microM colchicine to culture dishes of normal cells. Calcium currents and calcium transients recorded from myoballs were similar to those in normal myotubes.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

未成熟的骨骼肌细胞,无论在体内还是体外,都表达高密度的T型钙电流和相对低密度的二氢吡啶受体,该蛋白被认为作为缓慢钙通道以及兴奋 - 收缩偶联的电压感受器发挥作用。尽管已经研究了电压感受器在引发肌浆游离钙升高(钙瞬变)中的作用,但T型电流的作用尚未被研究。在本研究中,我们使用膜片钳技术的全细胞模式结合钙指示剂Fluo-3,研究了正常和发育不全小鼠培养的肌管中与T型电流相关的钙瞬变。在正常和发育不全的肌管中,T型电流通过弱去极化激活,对于测试脉冲至约 -20 mV时达到最大值。在显示T型钙电流的正常肌管中,在低膜电位(-40至 -20 mV)时钙瞬变跟随电流的幅度和积分,但在高电位时则不然,在高电位时钙瞬变由肌浆网钙释放引起。去极化后15 ms时测量的至 -20 mV脉冲的钙瞬变幅度平均占由强的15 ms测试去极化引发的钙瞬变最大幅度的4.26 +/- 0.68%(n = 19)。在发育不全的肌管中,在仅表达T型电流的细胞以及同时具有T型电流和L型电流Idys的细胞中,在所有测试电位下钙瞬变都跟随钙电流的积分。此外,在表达心脏的、对二氢吡啶敏感的钙通道的发育不全肌管中,钙瞬变也跟随电流的幅度和时间进程。因此,在那些瞬变似乎是钙内流结果的情况下,它与钙电流的积分具有相同的时间进程。用1 s预脉冲使T型钙电流失活,或通过添加氨氯地平(0.3 - 1.0 mM)阻断电流,导致正常和发育不全肌管中的钙瞬变降低,二者相似。为了计算细胞内钙响应内流的预期变化,通过向正常细胞培养皿中添加0.5 microM秋水仙碱,将肌管转变为大致球形(肌球)。从肌球记录的钙电流和钙瞬变与正常肌管中的相似。(摘要截短至250字)

相似文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验