• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Ergonomic vascular access needle with blood-containment capability: clinical evaluation during arterial access procedures.

作者信息

Gray R J, Rundback J H, Dolmatch B L, Horton K M

机构信息

Department of Radiology, Washington Hospital Center, Washington, DC 20010, USA.

出版信息

J Vasc Interv Radiol. 1995 Jan-Feb;6(1):115-8. doi: 10.1016/s1051-0443(95)71073-9.

DOI:10.1016/s1051-0443(95)71073-9
PMID:7703575
Abstract

PURPOSE

To evaluate the performance of the ergonomic vascular access needle (EVAN), which is designed to contain blood while allowing for observation of pulsations before passage of a guide wire, in arterial catheterization.

MATERIALS AND METHODS

EVANs were used for initial puncture in 118 arterial access procedures. Visualization of pulsatile blood motion and containment of blood were prospectively evaluated. Results from 82 separate procedures performed with standard access needles were used as a control. Success or failure of guide-wire passage through the needle, number of attempts, guide-wire type, findings on the access vessel arteriogram, and complications were recorded for both groups.

RESULTS

In the EVAN group, 92% of procedures were successfully completed, usually within two attempts (82%). Success was independent of guide-wire type (P = .4) and was not significantly different from that of the control group (96%) (P = .37). In 89% of the EVAN procedures, contained pulsatile blood motion was observed before attempted guide-wire passage. Uncontrolled spraying of pulsatile blood did not occur unless the hemostasis valve was removed. In 16%, slow oozing of blood occurred through the needle hub, mainly during guide-wire passage. Oozing was common with floppy-tipped guide wires (46%) but was uncommon with stiffer-tipped wires (6%). There were no needle-related complications.

CONCLUSION

The EVAN provides protection from blood spray while allowing for successful guide-wire passage into the arterial system as often as standard access needles. However, slow periwire leakage occurs frequently with floppy-tipped guide wires.

摘要

相似文献

1
Ergonomic vascular access needle with blood-containment capability: clinical evaluation during arterial access procedures.
J Vasc Interv Radiol. 1995 Jan-Feb;6(1):115-8. doi: 10.1016/s1051-0443(95)71073-9.
2
Directional needle for antegrade guide wire placement with vertical arterial puncture.
Radiology. 1988 Jul;168(1):271-2. doi: 10.1148/radiology.168.1.3380973.
3
Catheterization of the radial or brachial artery in neonates and infants.新生儿及婴儿桡动脉或肱动脉插管术。
Paediatr Anaesth. 2005 Aug;15(8):677-82. doi: 10.1111/j.1460-9592.2004.01522.x.
4
A comparison of a 'J' wire and a straight wire in successful antegrade cannulation of the superficial femoral artery.
Clin Radiol. 2005 Jan;60(1):112-5. doi: 10.1016/j.crad.2004.06.014.
5
Valsalva maneuver prevents guide wire trouble associated with 22-gauge safe guide.瓦尔萨尔瓦动作可防止与22号安全导丝相关的导丝问题。
Tokai J Exp Clin Med. 2001 Oct;26(3):113-8.
6
Comparison of a 21G micropuncture needle and a regular 19G access needle for antegrade arterial access into the superficial femoral artery.21G微穿刺针与常规19G穿刺针用于顺行股浅动脉动脉穿刺的比较。
Cardiovasc Intervent Radiol. 2014 Apr;37(2):343-7. doi: 10.1007/s00270-013-0669-0. Epub 2013 Jul 10.
7
Arterial cutdown reduces complications after brachial access for peripheral vascular intervention.动脉切开术可减少外周血管介入治疗中经肱动脉穿刺后的并发症。
J Vasc Surg. 2016 Jul;64(1):149-54. doi: 10.1016/j.jvs.2016.02.019. Epub 2016 Mar 23.
8
Endovascular placement of an extraluminal femoropopliteal bypass graft in human cadavers.人体尸体腔内股腘动脉搭桥移植物的血管内放置。
Cardiovasc Intervent Radiol. 2005 Mar-Apr;28(2):209-14. doi: 10.1007/s00270-004-4135-x.
9
Bioengineered vascular access maintains structural integrity in response to arteriovenous flow and repeated needle puncture.生物工程血管通路在应对动静脉血流和反复针刺时保持结构完整性。
J Vasc Surg. 2012 Sep;56(3):783-93. doi: 10.1016/j.jvs.2012.02.030.
10
A novel, minimally invasive access technique versus standard 18-gauge needle set for femoral access.一种新的微创入路技术与标准 18 号针套件用于股动脉入路。
Catheter Cardiovasc Interv. 2012 Jun 1;79(7):1180-5. doi: 10.1002/ccd.23330. Epub 2012 Feb 14.