Polymethylmethacrylate (PMMA) contact lenses can alter corneal shape and induce corneal warpage or distortion. The purpose of our study was to determine the effects on the corneal topography after immediate refitting of long-term PMMA contact lens wearers into rigid gas permeable (RGP) materials. Six eyes with contact lens induced corneal warpage from PMMA contact lenses were assessed using the Topographical Mapping System-1. Statistical analysis was performed for the following variables prior to and approximately 6 months after contact lens refitting: best spectacle visual acuity, manifest refraction, surface regularity index, surface asymmetry index, keratometry, and simulated keratometry. Best spectacle visual acuity improved an average of 1.8 +/- 1.0 (mean +/- SD, P < 0.05) lines of Snellen visual acuity, while refraction did not change appreciably. The surface regularity index diminished by 0.51 +/- 0.32 (P = 0.01). The surface asymmetry index improved by 0.32 +/- 0.26 (P < 0.05). There was a good correlation between keratometry and simulated keratometry, and neither changed significantly after refitting with RGP contact lenses. All general topographic patterns remained unchanged throughout the study. Immediate refitting of long-term PMMA contact lens wearers into RGP materials of similar fit allows a slightly more regular and symmetric central corneal shape, which can result in improved spectacle visual acuity. The general corneal topographic patterns of contact lens induced corneal warpage did not change or improve after refitting to RGP material.

摘要

聚甲基丙烯酸甲酯(PMMA)隐形眼镜会改变角膜形状,导致角膜翘曲或变形。我们研究的目的是确定长期佩戴PMMA隐形眼镜的患者立即改用硬性透气性(RGP)材料后对角膜地形图的影响。使用地形测绘系统-1对6只因PMMA隐形眼镜导致角膜翘曲的眼睛进行了评估。在隐形眼镜重新配镜前及重新配镜后约6个月,对以下变量进行了统计分析:最佳矫正视力、显验光、表面规则性指数、表面不对称指数、角膜曲率计测量值和模拟角膜曲率计测量值。最佳矫正视力平均提高了1.8±1.0(平均值±标准差,P<0.05)行Snellen视力,而验光没有明显变化。表面规则性指数降低了0.51±0.32(P=0.01)。表面不对称指数提高了0.32±0.26(P<0.05)。角膜曲率计测量值和模拟角膜曲率计测量值之间有良好的相关性,改用RGP隐形眼镜后两者均无明显变化。在整个研究过程中,所有总体地形模式均保持不变。长期佩戴PMMA隐形眼镜的患者立即改用适配性相似的RGP材料,可使中央角膜形状稍微更规则、更对称,这可能会提高矫正视力。改用RGP材料后,隐形眼镜导致的角膜翘曲的总体角膜地形模式没有改变或改善。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验