Drawbacks of the constant-infusion technique for measurement of renal function.

作者信息

Van Acker B A, Koomen G C, Arisz L

机构信息

Department of Medicine, Academic Medical Center, Amsterdam, The Netherlands.

出版信息

Am J Physiol. 1995 Apr;268(4 Pt 2):F543-52. doi: 10.1152/ajprenal.1995.268.4.F543.

Abstract

We investigated the validity of the steady-state constant infusion method (CIM), in which quantitative urinary recovery and constant plasma concentrations of the solute infused are required. Successive 3-h clearances of inulin and p-aminohippuric acid (PAH) were determined for 27 h in 25 patients with renal disease. Results were compared with the standard method of bladder clearance (StM) and with a modified CIM (ModCIM). The 24-h urinary recovery was incomplete for both inulin and PAH. Mean 24-h ModCIM inulin clearance overestimated StM by 4.5 ml.min-1 x 1.73 m-2 (range 0-9, P < 0.001) independent of the extent of renal impairment and pointed to slow distribution and/or extrarenal clearance of inulin. For PAH, the difference between ModCIM and StM clearance was related to the average PAH clearance by ModCIM and StM (r = 0.78). Furthermore, neither plasma inulin nor PAH became completely constant, because of the circadian rhythm in renal function. In conclusion, the conditions of the steady-state CIM technique are not fulfilled, and the method is not suitable for accurate measurement of inulin and PAH clearance, especially when the clearance is low.