Suppr超能文献

椎体旋转的测量:佩德里奥尔法与雷蒙迪法的比较

Measurement of vertebral rotation: Perdriolle versus Raimondi.

作者信息

Weiss H R

机构信息

Katharina-Schroth-Spinal Deformities Rehabilitation Center, Sobernheim, Germany.

出版信息

Eur Spine J. 1995;4(1):34-8. doi: 10.1007/BF00298416.

Abstract

The measurement of vertebral rotation according to Perdriolle is widely used in the French-speaking and Anglo-American countries. Even in this measurement technique there may be a relatively high estimation error because of the not very accurate grading in steps of 5 degrees. The measurement according to Raimondi seems to be easier to use and is more accurate, with 2 degrees steps. The purpose of our study was to determine the technical error of both measuring methods. The apex vertebra of 40 curves on 20 anteroposterior (AP) radiographs were measured by using the Perdriolle torsion meter and the Regolo Raimondi. Interrater and intrarater reliability were computed. The thoracic Cobb angle was 43 degrees, the lumbar Cobb angle 36 degrees. The average rotation according to Perdriolle was 19.1 degrees thoracic (SD 11.14), 12.7 degrees lumbar (11.21). Measurement of vertebral rotation according to Raimondi showed an average rotation of 20.25 degrees in the thoracic region (11.40) and 13.4 degrees lumbar (10.92). The intrarater reliability was r = 0.991 (Perdriolle) and r = 0.997 (Raimondi). The average intrarater error was 1.025 degrees in the Perdriolle measurement and 0.4 degrees in the Raimondi measurement. Interrater error was on average 3.112 degrees for the Perdriolle measurement and 3.630 degrees for the Raimondi measurement. This shows that both methods are useful tools for the follow-up of vertebral rotation as projected on standard X-rays for the experienced clinical. The Raimondi ruler is easier to use and is slightly more reliable.

摘要

根据佩德里奥尔法测量椎体旋转度,在法语区国家和英美国家广泛应用。即便在这种测量技术中,由于以5度为步长的分级不够精确,仍可能存在相对较高的估计误差。根据雷蒙迪法进行的测量似乎更易于使用且更精确,步长为2度。我们研究的目的是确定这两种测量方法的技术误差。使用佩德里奥尔扭转计和雷戈洛·雷蒙迪法,对20张前后位(AP)X线片上40个弯曲的顶椎进行测量。计算了测量者间和测量者内的可靠性。胸椎科布角为43度,腰椎科布角为36度。根据佩德里奥尔法,胸椎平均旋转度为19.1度(标准差11.14),腰椎为12.7度(11.21)。根据雷蒙迪法测量椎体旋转度,胸椎区域平均旋转度为20.25度(11.40),腰椎为13.4度(10.92)。测量者内可靠性方面,佩德里奥尔法r = 0.991,雷蒙迪法r = 0.997。佩德里奥尔法测量者内平均误差为1.025度,雷蒙迪法为0.4度。测量者间误差方面,佩德里奥尔法平均为3.112度,雷蒙迪法为3.630度。这表明,对于有经验的临床医生而言,这两种方法都是用于在标准X线片上观察椎体旋转度随访的有用工具。雷蒙迪测量尺更易于使用,且可靠性略高。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验