Suppr超能文献

后交叉韧带重建术后髌腱自体移植物中胶原纤维的组织形态。绵羊模型的定量评估。

Collagen fibril organization in the patellar tendon autograft after posterior cruciate ligament reconstruction. A quantitative evaluation in a sheep model.

作者信息

Bosch U, Decker B, Möller H D, Kasperczyk W J, Oestern H J

机构信息

Department of Traumasurgery, Hannover Medical School, Germany.

出版信息

Am J Sports Med. 1995 Mar-Apr;23(2):196-202. doi: 10.1177/036354659502300212.

Abstract

We replaced the posterior cruciate ligament in 30 skeletally mature sheep with a patellar tendon autograft using the central third of the ipsilateral patellar tendon. The healing autograft was compared with the contralateral posterior cruciate ligament and the patellar tendons and posterior cruciate ligaments of nonoperated animals. The collagen fibril diameters were analyzed using transmission electron photomicrographs of fibril cross sections taken at six periods during the 2 years after surgery. The patellar tendon and posterior cruciate ligament were characterized by a broad, nongaussian distribution of collagen fibril diameters. The autografts shifted to a unimodal distribution by an increase of small-diameter collagen fibrils. The frequency of small-diameter fibrils measuring up to 100 nm was 99% after 2 years. At that time, these small-diameter fibrils represented 91.6% of the area covered by collagen fibrils. The mean diameter of the collagen fibrils in the autografts significantly decreased to 45% of the controls at Week 26 and remained at this level until the end of this study. The percentage of area covered by collagen fibrils per 1 micron 2 was 78% of the controls 2 years post-operatively. This study suggests that the patellar tendon autograft could not reproduce the collagen fibril organization of the posterior cruciate ligament. This may be a biologic factor responsible for inconsistent results in posterior cruciate ligament replacement.

摘要

我们使用同侧髌腱中央三分之一自体移植髌腱,对30只骨骼成熟的绵羊进行后交叉韧带置换。将愈合的自体移植组织与对侧后交叉韧带以及未手术动物的髌腱和后交叉韧带进行比较。在术后2年的6个时间段,利用胶原原纤维横截面的透射电子显微照片分析胶原原纤维直径。髌腱和后交叉韧带的胶原原纤维直径呈宽的非高斯分布。自体移植组织通过小直径胶原原纤维的增加转变为单峰分布。2年后,直径达100nm的小直径原纤维频率为99%。此时,这些小直径原纤维占胶原原纤维覆盖面积的91.6%。在第26周时,自体移植组织中胶原原纤维的平均直径显著降至对照的45%,并在此水平维持至本研究结束。术后2年,每1平方微米胶原原纤维覆盖面积的百分比为对照的78%。本研究表明,髌腱自体移植不能重现后交叉韧带的胶原原纤维结构。这可能是导致后交叉韧带置换结果不一致的生物学因素。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验