Olsen G M, Olson R J
John A. Moran Eye Center, University of Utah Health Sciences Center, Salt Lake City 84132, USA.
J Cataract Refract Surg. 1995 Mar;21(2):136-9. doi: 10.1016/s0886-3350(13)80500-7.
We report the incidence of retinal detachment (RD) in 1543 consecutive cases of cataract extraction in a prospective cohort study. Retinal detachment was significantly associated with intracapsular extraction, axial lengths of 24.0 mm or longer and an intact capsule, and capsulotomy in eyes with axial lengths of 24.0 mm or longer. The interval between capsulotomy and RD was significantly shorter in eyes with axial lengths of 24.0 mm or greater. An intraocular lens with stiff, vaulted, poly(methyl methacrylate) optics and a biconvex PMMA optic was associated with significantly less capsule opacification than lenses of other designs.
在一项前瞻性队列研究中,我们报告了1543例连续白内障摘除病例中视网膜脱离(RD)的发生率。视网膜脱离与囊内摘除、眼轴长度24.0毫米或更长且晶状体囊完整以及眼轴长度24.0毫米或更长的眼中的晶状体切开术显著相关。在眼轴长度为24.0毫米或更长的眼中,晶状体切开术至视网膜脱离的间隔时间明显更短。与其他设计的人工晶状体相比,具有硬的、拱形的聚甲基丙烯酸甲酯光学部和双凸聚甲基丙烯酸甲酯光学部的人工晶状体与明显更少的晶状体后囊混浊相关。