Suppr超能文献

全膝关节置换的对线:与胫骨假体周围透亮线的关系。

Alignment of total knee arthroplasty: the relationship to radiolucency around the tibial component.

作者信息

Harvey I A, Manning M P, Sampath S A, Johnson R, Elloy M A

机构信息

Walton Hospital, Liverpool, UK.

出版信息

Med Eng Phys. 1995 Apr;17(3):182-7. doi: 10.1016/1350-4533(95)95708-i.

Abstract

Between January 1982 and July 1985, 122 cemented 'Accord' total knee replacements were performed. Out of this number, 21 were lost to follow-up because of death (in 16), revision (2) due to infection, and failure to attend (3). The post-operative alignment of 101 prostheses were compared to the incidence of radiolucencies around the tibial component at 5 years follow-up. The mechanical axis was used as a reference. The mean alignment was 0.99 degrees valgus with a standard deviation of 2.48 degrees. Some 72% of knees were within 3 degrees and 94% within 5 degrees of true alignment. Using two methods of assessing radiolucencies there was a non-significant relationship between the alignment and radiolucencies. The alignment tolerance with this prosthesis is, therefore, at least 5 degrees.

摘要

1982年1月至1985年7月期间,共进行了122例骨水泥固定的“Accord”全膝关节置换术。其中,21例因死亡(16例)、因感染翻修(2例)和未复诊(3例)而失访。对101个假体的术后对线情况与随访5年时胫骨部件周围透亮线的发生率进行了比较。以机械轴作为参考。平均对线为外翻0.99度,标准差为2.48度。约72%的膝关节对线在真实对线的3度范围内,94%在5度范围内。使用两种评估透亮线的方法,对线与透亮线之间存在无显著意义的关系。因此,这种假体的对线公差至少为5度。