[Intravascular ultrasound assessment at the site of balloon angioplasty: comparison with quantitative coronary angiography].

作者信息

Yamashita Y, Takazawa K, Fujita M, Iketani T, Ibukiyama C

机构信息

Second Department of Internal Medicine, Tokyo Medical College.

出版信息

J Cardiol. 1994 Nov-Dec;24(6):423-31.

PMID:7823280
Abstract

The effect of coronary angioplasty is usually evaluated on the basis of coronary angiography. However, angiographic images taken after angioplasty vary and the angiographic assessment of the therapeutic success of angioplasty is limited by local disruptions and dissections at the site of the dilatation, which are often difficult to detect by angiography. Intravascular ultrasound imaging is a new method for evaluation of coronary dimensions and wall morphology. Quantitative coronary angiographic analysis was compared with intravascular ultrasound assessment after balloon angioplasty in 42 patients. A diagnostic ultrasound imaging catheter was used during percutaneous transluminal coronary angioplasty (PTCA) to image both the lesion and the vessel segment just proximal (reference segment). Correlation between angiographic and ultrasound findings of vessel diameters and areas at reference segments was closer (r = 0.78, 0.66) than at the sites of PTCA (r = 0.54, 0.36). Dilated sites were analyzed in two subgroups segregated by degree of lumen eccentricity. An eccentric vessel lumen, defined as a circular shape factor of less than 0.92, was present at 25 of 42 sites. The correlation between angiographic and ultrasonic cross sectional area was not as close for these eccentric segments (r = 0.37). The difference in luminal areas between eccentric lumens estimated by edge detection and densitometry methods was 0.93 +/- 0.3 mm2, significantly greater than 0.54 +/- 0.31 mm2 in the circular group (p < 0.01). Luminal area after balloon angioplasty is clinically important to confirm by intravascular ultrasound especially in patients with large differences in measured values by quantitative coronary angiography.

摘要

相似文献

1
[Intravascular ultrasound assessment at the site of balloon angioplasty: comparison with quantitative coronary angiography].
J Cardiol. 1994 Nov-Dec;24(6):423-31.
2
An explanation for discrepancy between angiographic and intravascular ultrasound measurements after percutaneous transluminal coronary angioplasty.
J Am Coll Cardiol. 1995 Mar 1;25(3):633-9. doi: 10.1016/0735-1097(94)00453-W.
3
Intravascular ultrasound imaging of human coronary arteries after percutaneous transluminal angioplasty: morphologic and quantitative assessment.经皮腔内血管成形术后人体冠状动脉的血管内超声成像:形态学和定量评估。
Am Heart J. 1991 Jul;122(1 Pt 1):212-20. doi: 10.1016/0002-8703(91)90779-h.
4
Assessment of the results of percutaneous transluminal coronary angioplasty using an integrated ultrasound imaging-angioplasty catheter.
Cathet Cardiovasc Diagn. 1994 Jun;32(2):108-12. doi: 10.1002/ccd.1810320203.
5
Comparison of lumen area after PTCA by IVUS and QCA.
Heart Vessels. 1997;Suppl 12:217-20.
6
[Intravascular sonography of the coronary vessels following percutaneous transluminal angioplasty].经皮腔内血管成形术后冠状动脉血管的血管内超声检查
Dtsch Med Wochenschr. 1991 Jan 18;116(3):81-6. doi: 10.1055/s-2008-1063585.
7
[Morphological and quantitative analysis of the mechanism of balloon angioplasty. An intravascular ultrasonic study].
Rev Esp Cardiol. 1996 Jan;49(1):13-21.
8
[Lumen enlargement in coronary angioplasty: qualitative and quantitative analysis of vascular mechanisms with intravascular ultrasound].
Z Kardiol. 1996 Apr;85(4):281-9.
9
Videodensitometric quantitative angiography after coronary balloon angioplasty, compared to edge-detection quantitative angiography and intracoronary ultrasound imaging.冠状动脉球囊血管成形术后的视频密度定量血管造影术,与边缘检测定量血管造影术和冠状动脉内超声成像的比较。
Eur Heart J. 2000 Apr;21(8):654-61. doi: 10.1053/euhj.1999.1853.
10
[The mechanism of percutaneous transluminal balloon angioplasty as assessed by intracoronary ultrasound].[经冠状动脉内超声评估经皮腔内球囊血管成形术的机制]
Zhonghua Nei Ke Za Zhi. 2001 May;40(5):303-5.