A comparative study was carried out in 350 women using VCu200 intrauterine devices (IUD) and 350 women using stainless steel ring (SSR) IUD for 5-18 years. The endometrial changes and shapes of IUD were studied. The results showed that the pregnancy rate was significantly lower in VCu200 group after 5 years of insertion. In spite of the oxidation, erosion or breakage of the copper wire, calcium deposit of even deformation of the IUD, they were not associated with an increased incidence of endometrial carcinoma and pelvic inflammatory disease. It is suggested that VCu200 IUD need not to be removed if the IUD keeps normal shape and the copper wire remains intact by X ray examination.

摘要

对350名使用VCu200宫内节育器(IUD)的女性和350名使用不锈钢环(SSR)宫内节育器达5至18年的女性进行了一项对比研究。研究了子宫内膜变化和宫内节育器的形状。结果显示,插入VCu200宫内节育器5年后,其妊娠率显著更低。尽管铜丝出现氧化、侵蚀或断裂,宫内节育器出现钙沉积甚至变形,但这些情况均与子宫内膜癌和盆腔炎发病率增加无关。建议如果通过X光检查发现宫内节育器形状正常且铜丝完整,则无需取出VCu200宫内节育器。