[A study on duration of using VCu200 intrauterine device].

作者信息

Liu Q, Huang Z, Cui L

机构信息

Xin Hua Hospital, Shanghai Second Medical University.

出版信息

Zhonghua Fu Chan Ke Za Zhi. 1995 Sep;30(9):518-21.

PMID:8556908
Abstract

OBJECTIVE

To make certain of the duration of using V-copper 200mm2 intrauterine device (VCu200 IUD).

METHODS

Six hundreds and sixty six pieces of VCu200 IUD used for different time period and removed for various reasons were analyzed. The life span of VCu200 IUD depended on corrosion, fragmentation and damage of copper wire and these parameters were measured on VCu200 IUD removed.

RESULTS

There were significant difference in copper wire fragmentation rate between tenth year-group and fifteenth year group which were 12.36%, 25.53% respectively (P < 0.001), and so were the expulsion rate of copper wire 2.54%, 9.57% respectively (P < 0.05). The copper loss and copper releasing rate in tenth year-group were 39.73%, 22.95%micrograms/day respectively. Copper corrosion resulted in fragmentation of copper wire which occurred the earliest in three years of use and expulsion of copper wire segment occurred after five years of use.

CONCLUSION

Comparing the above results with other copper intrauterine devices, it was suggested that the suitable duration of VCu200 IUD use was ten years.

摘要

相似文献

1
[A study on duration of using VCu200 intrauterine device].
Zhonghua Fu Chan Ke Za Zhi. 1995 Sep;30(9):518-21.
2
[Multiload Cu250 intrauterine devices and VCu200 intrauterine devices for women with previous failure of stainless steel ring intrauterine devices: a 5-year randomized clinical trial].
Zhonghua Fu Chan Ke Za Zhi. 1994 Aug;29(8):481-3, 511.
3
[Long-term clinical observation on VCu200 intrauterine devices].[VCu200宫内节育器的长期临床观察]
Zhonghua Fu Chan Ke Za Zhi. 1994 Sep;29(9):545-7, 544-5.
4
[Release of copper ions after insertion of VCu200 IUDs].[VCu200宫内节育器置入后铜离子的释放]
Shengzhi Yu Biyun. 1983 Aug;3(3):32-5.
5
[Use of modified intrauterine device (IUD) TCu 380 with chromium filaments in the immediate postpartum].[产后即时使用含铬丝的改良型宫内节育器(IUD)TCu 380]
Ginecol Obstet Mex. 2000 Feb;68:70-6.
6
Corrosion of a new copper-gold or copper-platinum intrauterine device.一种新型铜金或铜铂宫内节育器的腐蚀
J Biomed Mater Res. 1982 Nov;16(6):785-98. doi: 10.1002/jbm.820160605.
7
A randomized comparative clinical evaluation of the Steel Ring, the VCu200 and the TCu220c IUDs.钢环、VCu200和TCu220c宫内节育器的随机对照临床评估。
Contraception. 1986 May;33(5):443-54. doi: 10.1016/s0010-7824(86)80003-8.
8
Electrochemical effects of metals on IUDs.金属对宫内节育器的电化学效应。
Int J Fertil. 1977;22(3):155-161.
9
[The TCu380 IUD: initial international experimental results with the latest "T" family IUD].[TCu380宫内节育器:最新“T”型家族宫内节育器的首次国际实验结果]
Contracept Fertil Sex (Paris). 1985 Sep;13(9):973-8.
10
Copper IUDs.铜宫内节育器
Contracept Deliv Syst. 1983 Jul;4(3):175-85.