Optimal filtering and quality control of the signal-averaged ECG. High-fidelity 1-minute recordings.

作者信息

Lander P, Berbari E J, Lazzara R

机构信息

University of Oklahoma Health Sciences Center, Department of Medicine, Oklahoma City 73104.

出版信息

Circulation. 1995 Mar 1;91(5):1495-505.

PMID:7867191
Abstract

BACKGROUND

The clinical performance of the signal-averaged ECG (SAECG) for prediction of ventricular tachycardia (VT) depends on its quality, or final noise level. However, signal averaging is a statistical estimation procedure that is time-consuming and vulnerable to noise-induced error. The optimally filtered SAECG is proposed as a simple, quality-assured procedure requiring only 1 minute of data.

METHODS AND RESULTS

The optimally filtered SAECG is based on measures of signal variance and time-frequency representations. Forty subjects were studied to compare a 0.3-microV root-mean-square (RMS) noise endpoint SAECG with an optimally filtered 64-beat ensemble. Eight SAECGs were computed with noise endpoints of 1.0-through 0.3-microV RMS. Noise measurements were also made directly from the filtered SAECG. From these and previously published data, sensitivity was predicted as a function of noise endpoint. Measured QRS parameters and final noise were highly similar between the optimally filtered SAECG and the 0.3-microV RMS noise endpoint SAECG.

CONCLUSIONS

The optimally filtered 64-beat SAECG achieves a performance (equivalent noise reduction, signal definition, and mathematically predicted sensitivity for VT) similar to a 0.3-microV RMS noise endpoint average. Testing in a large clinical database is required to validate the method for routine clinical use. SAECGs terminated by use of different noise measurement techniques are not directly comparable because of measurement technique dependence. However, a formula is presented for comparison of statistics between studies that have used the most popular noise measurement techniques.

摘要

相似文献

1
Optimal filtering and quality control of the signal-averaged ECG. High-fidelity 1-minute recordings.
Circulation. 1995 Mar 1;91(5):1495-505.
2
Improved recognition of sustained ventricular tachycardia from SAECG by support vector machine.通过支持向量机提高从信号平均心电图中识别持续性室性心动过速的能力。
Anadolu Kardiyol Derg. 2007 Jul;7 Suppl 1:112-5.
3
[Recording of atrial and ventricular signal averaged ECGs in patients with mitral valve prolapse syndrome].[二尖瓣脱垂综合征患者心房和心室信号平均心电图记录]
Pol Merkur Lekarski. 1998 Jun;4(24):302-5.
4
[The electrocardiogram of high resolution during ventricular tachycardia].[室性心动过速时的高分辨率心电图]
Arq Bras Cardiol. 1994 Jun;62(6):389-93.
5
Comparison between QRS duration at standard ECG and signal-averaging ECG for arrhythmic risk stratification after surgical repair of tetralogy of fallot.法洛四联症手术修复后心律失常风险分层中标准心电图与信号平均心电图的QRS波时限比较。
J Cardiovasc Electrophysiol. 2005 Mar;16(3):288-92. doi: 10.1046/j.1540-8167.2005.40312.x.
6
The signal-averaged ECG becomes late potential-positive at low noise levels in healthy subjects.在健康受试者中,信号平均心电图在低噪声水平时会出现晚期电位阳性。
Eur Heart J. 1995 Nov;16(11):1731-5.
7
[Evaluation for micropotential analysis by signal-averaged ECG using Holter monitoring].[使用动态心电图监测通过信号平均心电图进行微电位分析的评估]
Nihon Rinsho. 1995 Feb;53(2):321-7.
8
Absence of change of signal-averaged electrocardiogram identifies patients with ventricular arrhythmias who are non-responders to amiodarone.信号平均心电图无变化可识别对胺碘酮无反应的室性心律失常患者。
Int J Cardiol. 2002 Apr;83(1):47-55. doi: 10.1016/s0167-5273(02)00011-6.
9
Abnormal signal-averaged electrocardiogram (SAECG) in obesity.肥胖患者的异常信号平均心电图(SAECG)
Obes Res. 2000 Jan;8(1):20-8. doi: 10.1038/oby.2000.4.
10
[Methods for the detection of ventricular late potentials. High amplification ECG, signal averaging technic, frequency analysis and intracardiac mapping].[心室晚电位检测方法。高放大倍数心电图、信号平均技术、频率分析及心内标测]
Herz. 1988 Jun;13(3):147-59.

引用本文的文献

1
[Functional late potential analysis in the 24-hour electrocardiogram].[24小时心电图中的功能性晚电位分析]
Herzschrittmacherther Elektrophysiol. 1997 Dec;8(4):245-54. doi: 10.1007/BF03042615.
2
Noise reduction in magnetocardiography by singular value decomposition and independent component analysis.通过奇异值分解和独立成分分析降低心磁图中的噪声
Med Biol Eng Comput. 2006 Jun;44(6):489-99. doi: 10.1007/s11517-006-0055-z. Epub 2006 May 3.