Pidde T J, Little J W
Seattle Veterans Affairs Medical Center, WA 98108.
J Am Paraplegia Soc. 1994 Oct;17(4):168-70. doi: 10.1080/01952307.1994.11735931.
This report concerns a patient with bilateral hydronephrosis due to a tight external condom catheter retention strap. Urodynamics with fluoroscopy and cystoscopy failed to demonstrate bladder outlet obstruction, urethral stricture, uretero-vesicle junction abnormality, or other explanations for the bilateral hydronephrosis. The hydronephrosis resolved when the external condom catheter retention strap was eliminated. The authors emphasize the importance of patient education to prevent this problem and encourage alertness by clinicians to assess appropriateness of external condom catheter use.
本报告涉及一名因外部避孕套导尿管固定带过紧导致双侧肾积水的患者。荧光透视下的尿动力学检查及膀胱镜检查未能发现膀胱出口梗阻、尿道狭窄、输尿管膀胱连接部异常或其他导致双侧肾积水的原因。去除外部避孕套导尿管固定带后,肾积水得以缓解。作者强调患者教育对于预防该问题的重要性,并鼓励临床医生提高警惕,评估外部避孕套导尿管使用的合理性。