Burrow M F, Taniguchi Y, Nikaido T, Satoh M, Inai N, Tagami J, Takatsu T
Tokyo Medical and Dental University, Department of Operative Dentistry, Japan.
J Dent. 1995 Feb;23(1):41-5. doi: 10.1016/0300-5712(95)90659-6.
The effect of temperature and relative humidity (RH) on the early tensile bond strengths to bovine dentine of two bonding systems (Liner Bond System, and Scotchbond Multi-purpose), and an experimental system (KB-110) were tested. Two environmental conditions, room temperature (23 degrees C/50% RH) and oral temperature (30 degrees C/80% RH), were used in a controlled temperature and humidity chamber. Bond strengths were recorded immediately after, 10 min and 24 h following light curing. The tensile bond strengths did not vary between the two test conditions, but the mode of fracture was observed to change. The 30 degrees C/80% RH condition exhibited a slightly greater degree of adhesive type failures compared with the 23 degrees C/50% RH group. This was particularly so for the experimental system, indicating that different bonding systems may be more or less sensitive to changes in RH and temperature. Failures occurred partially or totally within the resin composite at the early test times, and it was concluded that the bond strengths of the systems tested tended to exceed the early cohesive strengths of the resin composite.
测试了温度和相对湿度(RH)对两种粘结系统(线性粘结系统和多功能思高粘结剂)以及一种实验系统(KB - 110)与牛牙本质早期拉伸粘结强度的影响。在可控温湿度试验箱中采用两种环境条件,即室温(23℃/50%RH)和口腔温度(30℃/80%RH)。在光固化后即刻、10分钟和24小时记录粘结强度。两种测试条件下的拉伸粘结强度没有差异,但观察到断裂模式发生了变化。与23℃/50%RH组相比,30℃/80%RH条件下表现出稍高程度的粘结剂型失败。实验系统尤其如此,表明不同的粘结系统对RH和温度变化的敏感程度可能或多或少有所不同。在早期测试时间,失败部分或全部发生在树脂复合材料内部,并且得出结论,所测试系统的粘结强度往往超过树脂复合材料的早期内聚强度。