Br J Anaesth. 1994 Jun;72(6):686-7. doi: 10.1093/bja/72.6.686.

Abstract

We have compared the effects of two different frequencies of train-of-four stimulation of the ulnar nerve (2-Hz stimulation once every 10 or 20 s) on onset time and potency of atracurium, vecuronium and mivacurium during balanced anaesthesia. The adductor pollicis EMG was recorded simultaneously in both hands of 24 children aged 2-12 yr. After administration of an ED50 dose of each blocker, onset times were mean 21 (SEM 10) s shorter (P < 0.05) and decreases in neuromuscular function were 22 (3)% greater (P < 0.001) in the hand which was stimulated once every 10 s. We conclude that it is not possible to compare potency estimates of neuromuscular blocking agents if different stimulation patterns have been used.

摘要

我们比较了在平衡麻醉期间,两种不同频率的尺神经四个成串刺激(每10或20秒进行一次2赫兹刺激)对阿曲库铵、维库溴铵和米库氯铵起效时间及效能的影响。同时记录了24名2至12岁儿童双手的拇收肌肌电图。给予每种阻滞剂的ED50剂量后,每10秒接受一次刺激的那只手的起效时间平均缩短21(标准误10)秒(P<0.05),神经肌肉功能降低幅度大22(3)%(P<0.001)。我们得出结论,如果使用了不同的刺激模式,就不可能比较神经肌肉阻滞剂的效能估计值。