J Prosthet Dent. 1994 Aug;72(2):194-203. doi: 10.1016/0022-3913(94)90080-9.
The wear of human dental enamel against amalgam, Concise composite, SR-Isosit Inlay/Onlay composite, Vitadur-N glazed porcelain, unglazed IPS Empress ceramic, and enamel (control) was investigated by use of a modified stress cycling machine. Testing was carried out in water and in citric acid (pH 4) and the enamel-material couples were subjected to 25,000 cycles of wear with a maximum load of 40 N. Tooth profile reduction was measured at baseline and at 5000 cyclic intervals with a computer image analysis program. The depth of the wear scars on material specimens was analyzed with a profilometer. All materials produced increased enamel wear in acid. Vitadur-N glazed porcelain was found to be the most destructive to human dental enamel, and this was closely followed by Empress and enamel.
利用改良的应力循环试验机,研究了人类牙釉质与汞合金、简洁复合树脂、SR-Isosit嵌体/高嵌体复合树脂、Vitadur-N 釉面瓷、未上釉的IPS Empress 陶瓷以及牙釉质(对照)之间的磨损情况。试验在水和柠檬酸(pH 4)中进行,牙釉质 - 材料组合经受了25000次循环磨损,最大载荷为40 N。使用计算机图像分析程序在基线和每5000次循环间隔测量牙齿轮廓减小情况。用轮廓仪分析材料样本上磨损瘢痕的深度。所有材料在酸性环境中都会使牙釉质磨损增加。发现Vitadur-N釉面瓷对人类牙釉质破坏最大,其次是Empress陶瓷和牙釉质。