A method for determining the selenium content of infant formulas is proposed. It includes wet digestion with nitric acid and hydrogen peroxide in medium pressure teflon bombs in a microwave oven and determination by graphite furnace atomic absorption spectrometry (GFAAS). The absence of interferences is checked. Values obtained for the limit of detection (19.4 ng/g), precision (RSD = 2.2%) and accuracy by analysis of a reference material show that the method is reliable.

摘要

提出了一种测定婴儿配方奶粉中硒含量的方法。该方法包括在微波炉中使用中压聚四氟乙烯消解罐,用硝酸和过氧化氢进行湿法消解,并通过石墨炉原子吸收光谱法(GFAAS)进行测定。检查是否存在干扰。通过分析参考物质获得的检测限(19.4 ng/g)、精密度(RSD = 2.2%)和准确度值表明该方法可靠。