Suppr超能文献

先天性髋关节发育不良继发骨关节炎的非骨水泥型全髋关节置换术。

Autophor cementless total hip arthroplasty for osteoarthrosis secondary to congenital hip dysplasia.

作者信息

Ivory J P, Kershaw C J, Choudhry R, Parmar H, Stoyle T F

机构信息

Department of Orthopaedic Surgery, Glenfield General Hospital, Leicester, United Kingdom.

出版信息

J Arthroplasty. 1994 Aug;9(4):427-33. doi: 10.1016/0883-5403(94)90054-x.

Abstract

The authors present a consecutive series of 38 arthroplasties for osteoarthrosis secondary to hip dysplasia. All arthroplasties were performed by a single surgeon using Mittelmeier II (Autophor, Osteo AG, Selzach, Switzerland) ceramic cementless components. Crowe grades of subluxation were 60% grade I, 16% grade II, 12% grade III, and 12% grade IV. In all cases, the acetabular component was seated in the true acetabulum. The mean follow-up period was 75 months (range, 40-122 months). By the time of review, six hips (16%) had required revision for aseptic loosening, mainly of the femoral component. Good or excellent results were achieved in only 63% of the patients. In the group of surviving arthroplasties, the median Charnley hip scores before surgery were: pain, 2; movement, 3; and walking, 3. After surgery, the scores were: pain, 5; movement, 5; and walking, 6. All improvements were significant. The mean postoperative Harris hip score was 84. Poor scores were associated with contralateral hip disease (2 cases) and spina bifida (2 cases), significantly affecting function. The Autophor prosthesis can produce satisfactory results in some of these young patients with hip dysplasia. However, femoral loosening is a major problem and because of this, the authors have since changed to a newer stem design.

摘要

作者报告了一系列连续38例针对髋关节发育不良继发骨关节炎的关节置换手术。所有关节置换手术均由同一位外科医生使用Mittelmeier II(Autophor,Osteo AG,瑞士塞尔察赫)陶瓷非骨水泥假体进行。髋关节半脱位的Crowe分级为:I级60%,II级16%,III级12%,IV级12%。所有病例中,髋臼假体均置于真髋臼内。平均随访期为75个月(范围40 - 122个月)。到复查时,6例髋关节(16%)因无菌性松动需要翻修,主要是股骨假体。仅63%的患者获得了良好或优秀的结果。在存活的关节置换组中,术前Charnley髋关节评分中位数为:疼痛2分,活动3分,行走3分。术后评分分别为:疼痛5分,活动5分,行走6分。所有改善均具有显著性。术后Harris髋关节平均评分为84分。低分与对侧髋关节疾病(2例)和脊柱裂(2例)相关,显著影响功能。Autophor假体在一些患有髋关节发育不良的年轻患者中可产生满意的结果。然而,股骨松动是一个主要问题,因此,作者此后已改用一种更新的假体柄设计。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验