Miyamoto H, Hamada T, Harada R, Sakao Y, Hata E
Department of Surgery, Mitsui Memorial Hospital, Tokyo, Japan.
Kyobu Geka. 1994 Oct;47(11):903-5.
A felt-like bioabsorbable prosthesis (Polyglycolic Acid (PGA) pledget and sheet; Medifit feft) was used for pulmonary fistula in a total of 10 patients. "Fibrin glue A" was absorbed into the PGA prosthesis previously. And next, the part of pulmonary fistula was coated with "Fibrin glue B", and then covered with the fibrin-absorbed PGA prosthesis. The prosthesis adhered to the diseased part of pulmonary pleura immediately, and therefore, in all these 10 patients, the post-operative air-leakage was stopped up to 4 days and neither side effect nor complication was observed.
一种毡状生物可吸收假体(聚乙醇酸(PGA)棉片和薄片;Medifit feft)用于10例肺瘘患者。“纤维蛋白胶A”预先被吸收到PGA假体中。接下来,用“纤维蛋白胶B”覆盖肺瘘部位,然后用吸收了纤维蛋白的PGA假体覆盖。假体立即粘附于肺胸膜病变部位,因此,在这10例患者中,术后漏气均在4天内停止,未观察到副作用或并发症。