Magnetic resonance imaging of rodent tumors using radiofrequency gradient echoes.

作者信息

Karczmar G S, River J N, Goldman Z, Li J, Weisenberg E, Lewis M Z, Liu K

机构信息

Department of Radiology, University of Chicago Medical Center, IL 60637.

出版信息

Magn Reson Imaging. 1994;12(6):881-93. doi: 10.1016/0730-725x(94)92029-x.

DOI:10.1016/0730-725x(94)92029-x
PMID:7968288
Abstract

This paper evaluates the use of radiofrequency (RF) magnetic field gradient echoes to provide contrast in magnetic resonance (MR) images of model tumors. Decay of RF gradient echoes as a function of evolution time was measured and sensitivity of the decay to changes in blood pressure was evaluated. Previous investigators have demonstrated that static field (B0) gradient echoes provide MR image contrast which is sensitive to the rate of self-diffusion of tissue water and may also be sensitive to the rate of tissue perfusion. Gradient echoes produced by RF magnetic field gradients provide a useful alternative to the conventional B0 methods. Unlike B0 gradient echoes RF gradient echoes are relatively insensitive to local magnetic susceptibility gradients and to magnetic field gradients produced by eddy currents. Differences between the two methods may be particularly significant for studies of tumors where large concentrations of deoxyhemoglobin and other paramagnetic substances may cause significant susceptibility gradients. Mammary adenocarcinomas subcutaneously implanted in the flanks of female Fisher rats were studied. Magnetic resonance experiments were performed at 2 T. A surface coil was used to provide an RF gradient and to excite and detect signals from the tumors. The decay of echo amplitude as a function of evolution time was measured and the decay at short and long evolution times was analyzed independently to calculate two apparent diffusion coefficients (ADCs). The preparation was extremely stable and the standard error for 10 consecutive measurements of gradient echo amplitude made over 30-60 min with an RF gradient strength of 50 kHz/cm, gradient duration of 1 ms (i.e., 50 cycles/cm), and echo evolution time (td) of 1 s was generally +/- 0.8%. The ADC calculated from the decay at short evolution times was approximately 3 x 10(-5) cm2/s. The ADC calculated from the decay at longer evolution times was approximately 0.5 x 10(-5) cm2/s. Both ADCs decreased immediately following sacrifice and administration of Hydralazine. The experiments demonstrate that measurements of RF gradient echo amplitudes in tumors can be made in vivo with a high degree of reproducibility and suggest that RF gradient echo amplitudes are sensitive to acute physiological changes in tumors. This method may be useful for characterization of tumors and prediction and monitoring of effects of therapeutic agents.

摘要

相似文献

1
Magnetic resonance imaging of rodent tumors using radiofrequency gradient echoes.
Magn Reson Imaging. 1994;12(6):881-93. doi: 10.1016/0730-725x(94)92029-x.
2
Radiofrequency magnetic field gradient echoes have reduced sensitivity to susceptibility gradients.射频磁场梯度回波对磁化率梯度的敏感性降低。
Magn Reson Imaging. 1995;13(6):791-7. doi: 10.1016/0730-725x(95)00051-h.
3
Effects of hyperoxia on T2* and resonance frequency weighted magnetic resonance images of rodent tumours.
NMR Biomed. 1994 Mar;7(1-2):3-11. doi: 10.1002/nbm.1940070103.
4
Transmit Array Spatial Encoding (TRASE) using broadband WURST pulses for RF spatial encoding in inhomogeneous B0 fields.使用宽带WURST脉冲进行传输阵列空间编码(TRASE),用于非均匀B0场中的射频空间编码。
J Magn Reson. 2016 Jul;268:36-48. doi: 10.1016/j.jmr.2016.04.005. Epub 2016 Apr 8.
5
MRI using radiofrequency magnetic field phase gradients.使用射频磁场相位梯度的磁共振成像。
Magn Reson Med. 2010 Jan;63(1):151-61. doi: 10.1002/mrm.22188.
6
An alternative to GRASE: toward spin-echo-like contrast with independent reconstruction of gradient-echo images.
Magn Reson Med. 1996 Nov;36(5):804-8. doi: 10.1002/mrm.1910360523.
7
Separation of water and fat MR images in a single scan at .35 T using "sandwich" echoes.
J Magn Reson Imaging. 1996 Nov-Dec;6(6):909-17. doi: 10.1002/jmri.1880060612.
8
[Myocardial microcirculation in humans--new approaches using MRI].[人类心肌微循环——磁共振成像的新方法]
Herz. 2003 Mar;28(2):74-81. doi: 10.1007/s00059-003-2451-6.
9
High-resolution MRI encoding using radiofrequency phase gradients.采用射频相位梯度的高分辨率 MRI 编码。
NMR Biomed. 2013 Nov;26(11):1602-7. doi: 10.1002/nbm.3023. Epub 2013 Sep 6.
10
Dual optimization method of radiofrequency and quasistatic field simulations for reduction of eddy currents generated on 7T radiofrequency coil shielding.用于减少7T射频线圈屏蔽上产生的涡流的射频和准静态场模拟的双重优化方法。
Magn Reson Med. 2015 Nov;74(5):1461-9. doi: 10.1002/mrm.25424. Epub 2014 Nov 3.

引用本文的文献

1
Diagnostic value of increased diffusion weighting of a steady-state free precession sequence for differentiating acute benign osteoporotic fractures from pathologic vertebral compression fractures.稳态自由进动序列扩散加权增加对鉴别急性良性骨质疏松性骨折与病理性椎体压缩骨折的诊断价值
AJNR Am J Neuroradiol. 2001 Feb;22(2):366-72.