在一名喉部偏斜的清醒患者中使用喉罩辅助纤维支气管镜气管插管。

Use of the laryngeal mask for fibrescope-aided tracheal intubation in an awake patient with a deviated larynx.

作者信息

Asai T

机构信息

Department of Anaesthesiology, Kansai Medical University, Osaka, Japan.

出版信息

Acta Anaesthesiol Scand. 1994 Aug;38(6):615-6. doi: 10.1111/j.1399-6576.1994.tb03962.x.

Abstract

I report a case in which fibrescope-aided awake tracheal intubation was achieved using a laryngeal mask, in a patient with a mediastinal goitre in whom tracheal intubation with both a laryngoscope and a fibreoptic bronchoscope had failed. The tumour extended to the upper part of the mediastinum. The larynx and the upper segment of the trachea were displaced by the tumour. Awake tracheal intubation with both a laryngoscope and a fibreoptic bronchoscope failed. The laryngeal mask was then inserted without difficulty. After a fibreoptic bronchoscope had been covered by a plastic tube, the combination was passed through the laryngeal mask into the trachea. The fibreoptic bronchoscope and the laryngeal mask were removed, and a reinforced endotracheal tube was then inserted over the plastic tube into the trachea. The time for tracheal intubation was about 70 s. The laryngeal mask may allow easier location of the laryngeal inlet with a fibreoptic bronchoscope, and this technique is a useful alternative to the conventional technique of tracheal intubation in the patient with a deviated larynx.

摘要

我报告一例病例,该患者患有纵隔甲状腺肿,使用喉镜和纤维支气管镜进行气管插管均失败,而后通过喉罩辅助清醒气管插管成功。肿瘤延伸至纵隔上部,喉和气管上段被肿瘤移位。使用喉镜和纤维支气管镜进行清醒气管插管均失败。随后顺利插入喉罩。将纤维支气管镜用塑料管套住后,经喉罩插入气管。移除纤维支气管镜和喉罩,然后将加强型气管导管经塑料管插入气管。气管插管时间约为70秒。喉罩可使纤维支气管镜更容易找到喉入口,对于喉部移位的患者,该技术是传统气管插管技术的一种有用替代方法。

相似文献

6
Use of a fiberoptic bronchoscope to facilitate tracheal intubation after failed intubation using the Airtraq laryngoscope.
Acta Anaesthesiol Scand. 2010 Feb;54(2):256-7. doi: 10.1111/j.1399-6576.2009.02100.x.

引用本文的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验