Peripherally-placed central venous access ports: clinical and laboratory observations.

作者信息

Johnson J A, Didlake R H

机构信息

Department of Surgery, University of Mississippi Medical Center, Jackson 39216.

出版信息

Am Surg. 1994 Dec;60(12):915-9.

PMID:7992964
Abstract

The P.A.S. Port system is a totally implantable central venous access device consisting of a miniature titanium portal and a 5.8 French catheter that is specifically designed for implantation in the forearm. The configuration of this system combined with its unique placement technology provides a simplified alternative to conventional chest-placed systems. Our group has placed a total of 61 P.A.S. Port devices in 56 patients whose ages ranged from 9 months to 85 years and who were followed for a median of 672 days. Over this period of follow-up, these devices have demonstrated a low overall complication rate (13.1%), an infection rate of 6.6%, median event-free patency of 278 days, and exceptional patient acceptance. Placement of the P.A.S. Port system is easily performed as an outpatient procedure under local anesthesia and requires neither fluoroscopy nor a conventional operating room setting. In vitro measurement of infusion pressure across a P.A.S. Port and a conventional catheter system revealed much higher resistance in the peripherally placed device, but this was found to be of no clinical significance because infusion pressures generated by flow rates up to 750 mL/hr were well within the limits of clinically available infusion pumps. We recommend the P.A.S. Port system as a safe, durable, and effective alternative for patients in whom a chest-placed device is inappropriate or undesired.

摘要

相似文献

1
Peripherally-placed central venous access ports: clinical and laboratory observations.
Am Surg. 1994 Dec;60(12):915-9.
2
Radiologic placement of a low profile implantable venous access port in a pediatric population.小儿人群中低调可植入式静脉通路端口的放射学放置
Cardiovasc Intervent Radiol. 2001 Nov-Dec;24(6):395-9. doi: 10.1007/s00270-001-0071-1. Epub 2001 Nov 8.
3
PAS-Port: a new implantable vascular access device for arm placement: experiences from the first two years.
Eur J Surg. 1995 May;161(5):323-6.
4
Comparison between peripherally implanted ports and externally sited catheters for long-term venous access.外周植入式端口与外置导管用于长期静脉通路的比较。
Ann R Coll Surg Engl. 1994 Jan;76(1):33-8.
5
Peripherally placed totally implantable venous-access port systems of the forearm: clinical experience in 763 consecutive patients.前臂外周完全植入式静脉通道端口系统:763 例连续患者的临床经验。
Cardiovasc Intervent Radiol. 2010 Dec;33(6):1159-67. doi: 10.1007/s00270-010-9854-6. Epub 2010 Apr 23.
6
Chest port placement with use of the single-incision insertion technique.经单一切口插入技术行胸部端口放置。
J Vasc Interv Radiol. 2009 Nov;20(11):1464-9. doi: 10.1016/j.jvir.2009.07.035.
7
Comparison of totally implanted reservoirs with external catheters as venous access devices in pediatric oncologic patients.小儿肿瘤患者中完全植入式贮器与外置导管作为静脉通路装置的比较。
Surg Gynecol Obstet. 1988 Aug;167(2):141-4.
8
A peripherally implanted permanent central venous access device.一种外周植入式永久性中心静脉通路装置。
Obstet Gynecol. 1991 Dec;78(6):1138-42.
9
Conversion of temporary hemodialysis catheters to permanent hemodialysis catheters: a retrospective study of catheter exchange versus classic de novo placement.临时血液透析导管转换为永久性血液透析导管:导管更换与经典重新置管的回顾性研究
Semin Dial. 2005 Sep-Oct;18(5):425-30. doi: 10.1111/j.1525-139X.2005.00081.x.
10
A trial with a new peripheral implanted vascular access device.一项关于新型外周植入式血管通路装置的试验。
Oncol Nurs Forum. 1990 Nov-Dec;17(6):891-6.