Abstract

Tuning fork tests are subjective and response bias must be accounted for when determining their validity as diagnostic tools. A significant proportion of patients who present for otologic evaluation have mixed hearing loss and it is important to know how this group responds to tuning fork testing. The need for masking in audiometry is indisputable but its role in tuning fork testing has never been established. The purpose of this study was to determine the sensitivity of tuning fork tests. The Weber, unmasked and masked Rinne, and Bing tests were administered in a prospective, random, and blind manner to 68 patients referred for audiologic assessment. Patients found to have normal hearing served as the control group. Signal Detection Theory was used to compare the results to pure-tone air- and bone-conduction audiometry. Overall the Rinne is an unbiased test with a sensitivity of 0.84 regardless of the type, severity, or frequency of hearing loss. This is not improved by masking. There is no role for either the Weber or Bing as independent tests. Mixed hearing loss behaves as conductive hearing loss. The Rinne without masking should be administered to patients suspected of having a hearing loss.

摘要

音叉试验具有主观性,在确定其作为诊断工具的有效性时必须考虑反应偏差。前来进行耳科评估的患者中有很大一部分存在混合性听力损失,了解这一群体对音叉测试的反应很重要。听力测定中掩蔽的必要性是无可争议的,但它在音叉测试中的作用从未得到确定。本研究的目的是确定音叉试验的敏感性。对68名转诊进行听力评估的患者以前瞻性、随机和盲法方式进行了韦伯试验、未掩蔽和掩蔽的林纳试验以及宾氏试验。听力正常的患者作为对照组。使用信号检测理论将结果与纯音气导和骨导听力测定结果进行比较。总体而言,无论听力损失的类型、严重程度或频率如何,林纳试验都是一种无偏差的试验,敏感性为0.84。掩蔽并不能提高其敏感性。韦伯试验或宾氏试验都不适合作为独立的测试。混合性听力损失表现为传导性听力损失。对于疑似有听力损失的患者,应进行未掩蔽的林纳试验。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验