PD-related infections of standard and different disconnect systems.

作者信息

Tofte-Jensen P, Klem S, Nielsen P K, Olgaard K

机构信息

Department of Nephrology, Rigshospitalet, University of Copenhagen, Denmark.

出版信息

Adv Perit Dial. 1994;10:214-7.

PMID:7999831
Abstract

A review of 332 patients initiating continuous ambulatory peritoneal dialysis (CAPD) treatment from January 1988 throughout September 1993, with a total observation time of 5237 patient-months. Seven peritoneal dialysis (PD) systems were used, three of which were comparable regarding patient characteristics: standard system (Baxter) and two disconnect systems, Twinbag (Baxter) and Gemini (Gambro). The two disconnect systems were identical in principle, except that Twinbag used iodine as disinfectant of connections and Gemini used alcohol as disinfectant. We found a reduction of peritonitis rates in one of the disconnect systems--Twinbag (iodine) 0.42 episodes/patient/year--and a slight increase in another disconnect system--Gemini (alcohol) 1.17 epi/patient/yr--compared to standard system (iodine) 0.92 epi/patient/yr. An improvement of exit-site infections (ESI) and tunnel infections was seen in both disconnect systems (0.17 and 0.20 epi/patient/yr) compared to standard system (0.35 epi/patient/yr). Introduction of disconnect CAPD system reduced peritonitis rates in systems using iodine as disinfectant. Disconnect systems reduced ESI, probably due to less trauma to the catheter. We recommend the use of disconnect CAPD systems using iodine instead of alcohol as disinfectant.

摘要

相似文献

1
PD-related infections of standard and different disconnect systems.
Adv Perit Dial. 1994;10:214-7.
2
Peritonitis incidence on a disconnect CAPD-system with or without the use of iodine clamp shields.
Adv Perit Dial. 1994;10:150-3.
3
The effectiveness of mupirocin preventing Staphylococcus aureus in catheter-related infections in peritoneal dialysis.莫匹罗星预防腹膜透析导管相关感染中金黄色葡萄球菌的有效性。
Adv Perit Dial. 2000;16:257-61.
4
A randomized multicenter trial to evaluate the effects of UV-Flash system on peritonitis rates in CAPD.
Adv Perit Dial. 1992;8:313-5.
5
Infection rates in end-stage renal disease patients treated with CCPD and CAPD using the UltraBag system.使用UltraBag系统接受持续循环腹膜透析(CCPD)和持续性非卧床腹膜透析(CAPD)治疗的终末期肾病患者的感染率。
Adv Perit Dial. 1995;11:164-7.
6
CAPD disconnect systems: UK peritonitis experience.持续性非卧床腹膜透析断开系统:英国腹膜炎经验
Adv Perit Dial. 1992;8:306-12.
7
Comparison of peritonitis rates in children on CAPD with spike connector versus two disconnect systems.采用加药接头的持续性非卧床腹膜透析(CAPD)儿童与采用两种断开连接系统的儿童腹膜炎发生率比较。
Adv Perit Dial. 1994;10:300-3.
8
Peritonitis in continuous ambulatory peritoneal dialysis: impact of a compulsory switch from a standard to a Y-connector system in a single North American Center.持续性非卧床腹膜透析中的腹膜炎:北美单一中心从标准连接系统强制转换为Y形连接系统的影响
Am J Kidney Dis. 1992 Apr;19(4):364-70. doi: 10.1016/s0272-6386(12)80455-0.
9
Comparison of two non-disconnect CAPD delivery systems.两种非断开式持续性非卧床腹膜透析(CAPD)输送系统的比较。
Adv Perit Dial. 1989;5:227-8.
10
A prospective study of peritoneal dialysis-related infections in CAPD patients with diabetes mellitus.
Adv Perit Dial. 1993;9:195-7.