Suppr超能文献

胃癌的术前评估:机械静脉注射造影剂的双期动态CT的价值

Preoperative assessment of gastric carcinoma: value of two-phase dynamic CT with mechanical iv. injection of contrast material.

作者信息

Cho J S, Kim J K, Rho S M, Lee H Y, Jeong H Y, Lee C S

机构信息

Department of Diagnostic Radiology, Chungnam University Hospital, Taejon, Korea.

出版信息

AJR Am J Roentgenol. 1994 Jul;163(1):69-75. doi: 10.2214/ajr.163.1.8010251.

Abstract

OBJECTIVE

The purpose of this study was to evaluate the utility of two-phase dynamic CT performed with mechanical IV injection of a bolus of contrast medium after oral intake of water in the preoperative staging of gastric cancers.

SUBJECTS AND METHODS

We performed incremental dynamic CT in 52 patients with pathologically proved gastric cancers. Dynamic CT findings were prospectively analyzed and correlated with surgical and histopathologic findings. A total of 150 ml of nonionic contrast medium was administered IV with a power injector at a flow rate of 5 ml/sec for 30 sec, and two-phase images were obtained at 30 sec (early phase) and 2 min (equilibrium phase) after the start of bolus injection.

RESULTS

Forty-one advanced gastric carcinomas showed a moderate to marked degree of heterogeneous enhancement in the early phase and homogeneous enhancement of the entire lesion in the equilibrium phase of dynamic CT. The primary tumors were correctly detected with dynamic CT in five (56%) of the nine early gastric cancers and in 41 (95%) of the 43 advanced gastric cancers. The overall detection rate of gastric cancers was 88% (46 of 52 cases). The accuracies of dynamic CT according to TNM staging in determining the depth of tumor invasion, the degree of serosal invasion, and regional lymph node metastasis were 65% (34 of 52 cases), 83% (38 of 46 cases), and 70% (32 of 46 cases), respectively.

CONCLUSION

Our findings show that two-phase incremental dynamic CT with mechanical IV injection of a bolus of contrast medium after oral intake of water improves the diagnostic accuracy of CT over that provided by conventional CT in the preoperative staging of gastric cancers.

摘要

目的

本研究旨在评估口服水后经机械静脉注射造影剂团注进行的双期动态CT在胃癌术前分期中的应用价值。

对象与方法

我们对52例经病理证实的胃癌患者进行了递增动态CT检查。对动态CT表现进行前瞻性分析,并与手术及组织病理学结果进行关联。使用高压注射器以5ml/秒的流速静脉注射150ml非离子型造影剂,持续30秒,在团注开始后30秒(早期)和2分钟(平衡期)获取双期图像。

结果

41例进展期胃癌在动态CT早期表现为中度至明显的不均匀强化,在平衡期整个病灶呈均匀强化。9例早期胃癌中有5例(56%)、43例进展期胃癌中有41例(95%)通过动态CT正确检测出原发肿瘤。胃癌的总体检出率为88%(52例中的46例)。动态CT根据TNM分期在确定肿瘤浸润深度、浆膜侵犯程度和区域淋巴结转移方面的准确率分别为65%(52例中的34例)、83%(46例中的38例)和70%(46例中的32例)。

结论

我们的研究结果表明,口服水后经机械静脉注射造影剂团注进行的双期递增动态CT在胃癌术前分期中比传统CT提高了诊断准确性。