Suppr超能文献

急诊科常用的各种冲洗技术的压力动态

Pressure dynamics of various irrigation techniques commonly used in the emergency department.

作者信息

Singer A J, Hollander J E, Subramanian S, Malhotra A K, Villez P A

机构信息

Department of Emergency Medicine, State University of New York at Stony Brook.

出版信息

Ann Emerg Med. 1994 Jul;24(1):36-40. doi: 10.1016/s0196-0644(94)70159-8.

Abstract

STUDY OBJECTIVE

To evaluate the pressure dynamics of common irrigation techniques used in the treatment of traumatic wounds.

DESIGN

Matched experimental trial.

PARTICIPANTS

Ten male volunteers.

INTERVENTIONS

Pressure curves were obtained while performing manual irrigation with 250-mL boluses of normal saline with 19-gauge needles on 35-mL syringes, 19-gauge needles on 65-mL syringes, IV bags pierced with 19-gauge needles, and plastic bottles pierced with 19-gauge needles. Measurements also were obtained using an IV bag with tubing attached to either a 19-gauge or 16-gauge needle within a pressure cuff inflated to 400 mm Hg.

RESULTS

Median peak pressures were 35 lb/in.2 (psi)(range, 25 to 40 psi) and 27.5 psi (range, 15 to 40 psi) using a 35-mL syringe and a 65-mL syringe, respectively. Median peak pressures with the IV bag and plastic bottle were 4 psi (range, 2 to 5.5 psi) and 2.3 psi (range, 1.2 to 4.5 psi), respectively. The IV bag in a pressure cuff generated pressures of 6 to 10 psi and 4 to 6 psi using 19-gauge and 16-gauge needles, respectively.

CONCLUSION

Both 35-mL and 65-mL syringes with a 19-gauge needle are effective in performing high-pressure irrigation in the range of 25 to 35 psi. The use of IV bags and plastic bottles should be discouraged when high-pressure irrigation is required.

摘要

研究目的

评估用于治疗创伤性伤口的常见冲洗技术的压力动态变化。

设计

配对实验性试验。

参与者

10名男性志愿者。

干预措施

使用配备19号针头的35毫升注射器、配备19号针头的65毫升注射器、用19号针头穿刺的静脉输液袋以及用19号针头穿刺的塑料瓶,以250毫升生理盐水大剂量进行手动冲洗时获取压力曲线。还使用了一个连接有19号或16号针头的静脉输液袋,该输液袋置于充气至400毫米汞柱的压力袖带内进行测量。

结果

使用35毫升注射器和65毫升注射器时,中位峰值压力分别为35磅力/平方英寸(psi)(范围为25至40 psi)和27.5 psi(范围为15至40 psi)。静脉输液袋和塑料瓶的中位峰值压力分别为4 psi(范围为2至5.5 psi)和2.3 psi(范围为1.2至4.5 psi)。置于压力袖带内的静脉输液袋使用19号针头时产生的压力为6至10 psi,使用16号针头时产生的压力为4至6 psi。

结论

配备19号针头的35毫升和65毫升注射器在25至35 psi范围内进行高压冲洗均有效。需要进行高压冲洗时,应避免使用静脉输液袋和塑料瓶。