• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Microwave ablation of the atrioventricular junction in vivo and ventricular myocardium in vitro and in vivo. Effects of varying power and duration on lesion volume.

作者信息

Yang X, Watanabe I, Kojima T, Takahashi Y, Kanada A, Kunimoto S, Kasamaki Y, Kondo K, Saito S, Ozawa Y

机构信息

Second Department of Internal Medicine, Nihon University School of Medicine, Tokyo, Japan.

出版信息

Jpn Heart J. 1994 Mar;35(2):175-91. doi: 10.1536/ihj.35.175.

DOI:10.1536/ihj.35.175
PMID:8022062
Abstract

Catheter ablation in ventricular tachycardia has achieved only limited success using direct current (DC) and radiofrequency (RF) energy, due to either high complication rates or a limited lesion size. Microwave energy represents a possible alternative source of energy for percutaneous ablation of the ventricular myocardium. However, an optimal method for titration of the dose of microwave energy to achieve the desired lesion volume has not yet been established. The safety and efficacy of microwave ablation of the atrioventricular (AV) junction were studied in 11 dogs in vivo. The relationship between lesion size following microwave ablation and the power output of or exposure duration to microwave energy was also examined at disparate sites in each superfused left ventricular epicardium in vitro. To observe the pathologic changes in the myocardium after microwave ablation, microwave ablation of the endocardium of the left ventricle was carried out in 9 dogs in vivo. Complete AV block was achieved in 10 of the above 11 dogs with a mean of 5 applications of microwave energy. The lesion volume in vitro demonstrated a parallel increase with power (r = 0.76) and duration (r = 0.81). The mean lesion volume at 30 sec was: at 10W, 0.8 +/- 1.6; 20 W, 34.7 +/- 10.3; 30 W, 34.7 +/- 22.4: 40 W, 64.7 +/- 64.4; 50 W, 87.2 +/- 42.3; 60 W, 85.8 +/- 38.1; 70 W, 124.7 +/- 36.5; 80 W, 134.2 +/- 49.0 mm3. The mean lesion volume at 80 W was: at 15 sec, 32.6 +/- 37.8; 30 sec, 101.2 +/- 46.4; 60 sec, 180.6 +/- 80.1; 120 sec, 291.8 +/- 122.7; and 180 sec, 459.3 +/- 204.6 mm3. The ablated lesions showed discrete, homogeneous coagulation necrosis with sharp margins from the adjacent normal myocardium. Microwave energy may thus be more effective than RF energy, and have a lower risk of complications and arrhythmogenesis than DC energy when used for ablation in ventricular tachycardia.

摘要

相似文献

1
Microwave ablation of the atrioventricular junction in vivo and ventricular myocardium in vitro and in vivo. Effects of varying power and duration on lesion volume.
Jpn Heart J. 1994 Mar;35(2):175-91. doi: 10.1536/ihj.35.175.
2
Relation between the size of lesions and arrhythmias produced by microwave catheter ablation with a special electrode device.
Jpn Circ J. 1994 Mar;58(3):214-21. doi: 10.1253/jcj.58.214.
3
[An experimental study of catheter ablation using microwave energy via coaxial electrode catheter].
Kokyu To Junkan. 1993 Oct;41(10):981-5.
4
Microwave ablation of the atrioventricular junction in open-chest dogs.
Bioelectromagnetics. 1995;16(2):97-105. doi: 10.1002/bem.2250160205.
5
Catheter ablation of the atrioventricular junction using a helical microwave antenna: a novel means of coupling energy to the endocardium.使用螺旋微波天线进行房室结导管消融:一种将能量耦合至心内膜的新方法。
Pacing Clin Electrophysiol. 1991 Dec;14(12):2105-13. doi: 10.1111/j.1540-8159.1991.tb06481.x.
6
Closed chest catheter desiccation of the atrioventricular junction using radiofrequency energy--a new method of catheter ablation.使用射频能量对房室交界区进行闭合式胸导管干燥——一种新的导管消融方法。
J Am Coll Cardiol. 1987 Feb;9(2):349-58. doi: 10.1016/s0735-1097(87)80388-1.
7
Advanced radiofrequency catheter ablation in canine myocardium.犬心肌组织中的高级射频导管消融术。
Am Heart J. 1994 Apr;127(4 Pt 1):851-7. doi: 10.1016/0002-8703(94)90553-3.
8
Cooled-tip ablation results in increased radiofrequency power delivery and lesion size in the canine heart: importance of catheter-tip temperature monitoring for prevention of popping and impedance rise.冷尖端消融可增加犬心脏的射频能量传递及损伤灶大小:导管尖端温度监测对预防“弹出”和阻抗升高的重要性
J Interv Card Electrophysiol. 2002 Feb;6(1):9-16. doi: 10.1023/a:1014140104777.
9
Microwave catheter ablation of myocardium in vitro. Assessment of the characteristics of tissue heating and injury.体外心肌微波导管消融。组织加热和损伤特征评估。
Circulation. 1994 May;89(5):2390-5. doi: 10.1161/01.cir.89.5.2390.
10
Microwave ablation of canine atrial tachycardia induced by aconitine.乌头碱诱发犬房性心动过速的微波消融
Am Heart J. 1995 May;129(5):1021-5. doi: 10.1016/0002-8703(95)90126-4.

引用本文的文献

1
Alternate energy sources for catheter ablation.
Curr Cardiol Rep. 1999 Jul;1(2):165-71. doi: 10.1007/s11886-999-0076-y.
2
Pulsing microwave energy: a method to create more uniform myocardial temperature gradients.脉冲微波能量:一种创建更均匀心肌温度梯度的方法。
J Interv Card Electrophysiol. 1997 Feb;1(1):57-65. doi: 10.1023/a:1009770803013.